HomeMy WebLinkAbout1969-02-11 Board of Survey Minutes 89v
FEBRUARY 11, 1969
' MEETING OF THE BOARD OF SURVEY SCHEDULED FOR
FEBRUARY 10 OPENED AT 7:50 P.M. IN BOOM 16, MUNICIPAL BUILD-
ING .
PRESENT WERE CHAIRMAN HODGKINS, SECRETARY FLORENCE,
BOARD MEMBERS WATT AND WHITE AND SUPERINTENDENT LOUANIS.
MINUTES OF PREVIOUS MEETING READ AND APPROVED.
READ LETTER FROM LESTER C. PEABODY REQUESTING
PARTIAL RELEASE OF THE BOND COVERING THE FIRST SECTION OF
RED GATE LANE IN THE AMOUNT OF $10, 000. 00. ACCORDING TO
THE SUPERINTENDENT, AN ESTIMATE OF THE REMAINING WORK
' WOULD COST $3, 000. 00; THEREFORE, HE RECOMMENDED RELEASE OF
$7, 000. 00.
MR. WHITE MOVED THAT THE BOARD' FOLLOW THE SUPER-
INTENDENT 'S RECOMMENDATION AND RELEASE $7, 000. 00, IIR. WATT
SECONDED AND IT WAS VOTED.
PRELIMINARY HEARING WAS HELD AT 6:00 P.M. RE-
GARDING THE APPROVAL, DISAPPROVAL OR MODIFICATION OF THE
LINES AND GRADES OF RANDALL ROAD AND LISA LANE AS SHOWN
ON PLANS SUBMITTED BY HAYES ENGINEERING INC.
MESSRS. HENRY AND WILLZAM ANGELINI, DEVELOPERS,
ATTENDED THE HEARING. A LIST OF ADDITIONS AND CORRECTIONS
WERE RECOMMENDED, AS FOLLOWS:
1. CHANGE V. C. SEWERS TO A. G. SEWERS AND NOTE PIPE
STRENGTH CLASS - RANDALL ROAD.
so
2. SHOW CURBING AT INTERSECTION OF WEST STREET AND
RANDALL ROAD.
3. SHOW GUTTER LINE PROFILES OF STREET INTERSECTIONS.
¢. HOW ARE ROADWAY SIDE SLOPES TO BE HANDLED IN THE
AREA OF COOLID09 ROAD? TYPICAL CROSS SECTION '
WOULD GO BEYOND PLAN NOTE "LIMIT OF CONSTRUCTION".
5. HOW ARE ROADWAY SIDE SLOPES TO BE HANDLED IN THE
AREAS OF PRIVATE PROPERTY ALONG RANDALL ROAD?
6. EXTEND DRAIN PIPE ON LOT ¢ LISA LANE 100 FEET
BACK FROM STREET LINE.
7. SUBMIT WORK DRAWING WITH CONTOUR LINES, COORDI-
NATES, ETC.
8. REDUCE VELOCITIES IN SEWER AND DRAIN LINES FROM
LISA LANE TO EASEMENT.
9. SET MINIMUM CELLAR FLOOR ELEVATIONS ON LOTS IN LOW
AREA ON RANDALL ROAD.
10. WATER MAIN AND SEWER AT SAME ELEVATION ON RANDALL
ROAD (STA. 6+00t TO 10+50t) AND LISA LANE (STA.
3+50t TO 5+00t). SEWER CONNECTIONS TO PROPERTY
WOULD RUN INTO WATER MAIN. SUGGEST LOWERING OF
SEWER TO A NORMAL 7-FOOT DEPTH OR RAISING THE PRO-
FILE GRADE.
11 . FURTHER STUDY OF 8-INCH SEWER OFF MONROE AVENUE
IN EASEMENT NEEDED. PLAN AND PROFILE DO NOT SHOW
ACTUAL FIELD CONDITIONS WHICH AFFECT METHOD OF
CONSTRUCTION WITHIN THE EASEMENT.
12. MAKE SLOPE AT END OF RANDALL ROAD 3:1 .
THE BOARD WILL RENDER A DECISION WHEN THE COR-
RECTIONS AND ADDITIONS ARE INCORPORATED IN THE PLAN.
MEETING ADJOURNED AT 8:18 P.M.
RESPECTFULLY SUBMITTED.
c �