HomeMy WebLinkAbout2017-06-15 RMLD Board of Commissioners MinutespyyN OF O'
yc Town of Reading
Meeting Minutes
co
Board - Committee - Commission - Council:
RMLD Board of Commissioners
Date: 2017-06-15
Building: Reading Municipal Light Building
Address: 230 Ash Street
Purpose: General Business
Attendees: Members - Present:
Time: 7:30 PM
Location: Winfred Spurr Audio Visual Room
Session: Open Session
Version:
Philip B. Pacino, Chairman -Secretary Pro Tem; David Hennessy, Vice
Chairman; Thomas O'Rourke, Commissioner; David Talbot, Commissioner.
Members - Not Present:
John Stempeck, Commissioner
Others Present:
RMLD: Coleen O'Brien, General Manager, Hamid Jaffari, Director of
Engineering and Operations, Jane Parenteau, Director of Integrated
Resources, Wendy Markiewicz, Director of Business Finance, and Tracy
Schultz, Executive Assistant
CAB: Dennis Kelley, Secretary, Citizens' Advisory Board
Guest: Mayhew Seavey, PLM Engineering
Public: Tony D'Arezzo, Resident, 130 John Street, Reading, MA
Minutes Respectfully Submitted By: Philip B. Pacino, Chairman, Secretary Pro Tem
Topics of Discussion:
Call Meeting to Order
Chairman Pacino called the meeting to order and announced that the meeting is being
videotaped at the RMLD office at 230 Ash Street, for distribution to the community television
stations in Reading, North Reading, Lynnfield, and Wilmington. Chairman Pacino expressed his
concern that he received a complaint from the North Reading Selectmen that North Reading
Cable Access and Media (NORCAM), North Reading's public access station, hasn't been
receiving DVDs of the meetings.
Ms. Parenteau explained that RMLD makes copies of the meeting DVDs and she will make sure
that they are being delivered.
Opening Remarks
Chairman Pacino read the RMLD Board of Commissioners' Code of Conduct and welcomed Mr.
Kelley from the Citizens Advisory Board. Mr. Kelley commented that the recent solar tour was
interesting. Chairman Pacino announced that Mr. Stempeck is away and would not be in
attendance this evening.
Public Comment
There were no Board Liaisons present and there was no public comment.
Page I I
Report RMLD Board Member Attendance at Citizens' Advisory Board Meeting May 24, 2017
Chairman Pacino stated that the CAB meeting's primary focus was the rate adjustments that
the Commission will examine this evening. The CAB voted to recommend that the Commission
approve the new rates.
Report of the'Chait,�_�
Chairman Pacino stated that he wanted to comment publicly that he saw a sign on Ash Street
that read "Hate has no home here" and that he totally endorses and agrees with that
statement.
The Wilmington solar ribbon cutting ceremony was held last Thursday and that project is now up
and running. The Commission had a strategic session with discussion and many assignments for
the group to come back with.
Chairman Pacino asked Mr. Kelly whether the CAB has determined who will be its members on
the Committee on Payment to the Town of Reading stands. Mr. Kelley replied that he will check
with Mr. Hooper.
General Manager's Report - Ms. O'Brien
Ms. O'Brien announced that RMLD Customer Service will be closed on Monday, July 3rd and
Tuesday, July 4th.
RMLD held a ribbon cutting ceremony at the community solar project at 326 Ballardvale on
Thursday. It was a great event. There is another ribbon cutting coming up for the peak
generator, but that date remains to be determined. In terms of community engagement, an
informational table on Shred the Peak will be set up at the Reading Lions Club Friends and Family
Day on June 17th, and at the Wilmington farmers' market on June 25th.
Info sessions will be held at local senior centers on various days in June. Ms. O' Brien will be
meeting with the North Reading Board of Selectmen on Monday, June 19th.
Mr. O'Rourke asked that event dates now be included in the Commission packets.
Quarterly Updates: Organizational L Reliability Reports - Ms. O'Brien and Mr. Jaffari (Attachment
1) -
Ms. O'Brien explained that she would be talking about the Organizational highlights. A report will
be issued in the first quarter of next year on the progress of. the Strategic Plan. The Six-year plan
was updated as part of the budget, and is ongoing every year. The electric system master plan
has essentially been completed by Mr. Jaffari and his group. There will be a final report and
presentation in September to show where we are with grid modernization and the entire
technological road map. The workforce development plan is wrapping up -that means career
development plans and rewritten job descriptions for all employees. We're in the final stages
and it has been quite an undertaking. A part of that is succession planning. As we've been
redoing the job descriptions we've been anticipating employees who may be retiring in 5 -years
and making sure that skill sets have been broadened, so other employees in those groups have
opportunities to move ahead.
RMLD now has a new review process that was just finalized. All managers are sitting down with
their employees and giving out goals. The process starts July 1, fiscal year 2018. Organizational
culture and employee satisfaction will be assessed; we will get a lot of input once the review
process begins. A year from now, everyone will be reviewed in the management union. The
labor union doesn't have a formal review process. There is an increase in efforts to fill vacant
positions. Engineering will now be composed of five system engineer positions. All five engineers
will be cross trained and capable of running the system.
Mr. O'Rourke suggested an employee survey. Ms. O'Brien stated that RMLD has a survey that is
part of what Leidos said to do; now that the reorganization is nearing completion, feedback can
Page 1 2
Quarterly Updates: Organizational & Reliability Reports - Ms. O'Brien and Mr. Jaffari (Attachment
1)
be solicited.
Ms. O' Brien continued: cross -divisional management training is occurring, as is leadership
training. Project management training will be held onsite at RMLD. Policies are ongoing. A risk
management plan, as far as power supply, is an ongoing process. Changes in financial business
processes are moving along. Assigning a compliance manager has not been done yet -figuring
out the best way to address that. Asset management plan putting in SpryPoint-an automated
quasi -work order stock timesheet system, that will serve as an interim while work order systems
are reviewed. There has never been a true work order system here. There's now a pilot program
in place for the interim program. The current work place is being enhanced; once the office is
painted and reorganized, Ms. O' Brien proposed a tour for the Commissioners in September.
Vice Chairman Hennessy asked if the leadership development for the management team has
already started.
Ms. O'Brien replied that there are a couple of levels of leadership. For middle management,
project management, supervisory skills, and conflict resolution have been put onto everyone's
career development plans. Middle management knows what they must take. Leadership in
unions will also be required to take courses.
Training plans for direct reporting managers are being developed.
Mr. Kelley asked, without a work order system, how have you been tracking labor and cost?
Ms. O'Brien replied, by using a paper stock sheet system. We will implement a full Work Order
system. It is being evaluated.
Mr. Kelley asked how were you doing inventory management then?
Ms. O'Brien answered that everything was being done manually. The stock sheet has now
become automated, and it has also become integrated. It's on tablets and is being piloted with
the troublemen and the Control Room.
Once that pilot is done it will be rolled out to everyone else and we'll get rid of the paper stock
sheets.
Mr. Jaffari stated that RMLD is making good progress on the Booth reliability recommendations.
Mr. Jaffari stated that he is glad to announce that the bus work at Station 5 is completed. That
substation is old and is nearing the end of its useful life so we're looking for land in the Wilmington
area to build a new substation. However, that will take 3 to 5 years to be completed. In the
interim, RMLD has made upgrades and rejuvenated the switchgear and reinsulated the bus in
the existing station. While doing so, asbestos was discovered, which has prolonged the project.
The switchgear's life has been extended for another 5 to 10 years.
GIS data collection is completed and the contractor's work is being checked. This is anticipated
to be completed by September 1 and then the data will be put into the engineering model so
analysis can be down with more accuracy. SCADA work is underway. This week, consultants are
upgrading SCADA and programming substation 3 and substation 4 to send telemetry data and
connect to Eversource and National Grid so RMLD can join the overall 115 kv network.
All critical substation items that were identified by UPG, the contractor that was brought in to test
substations, have been addressed and completed.
Mr. Kelley asked if a recent Wilmington outage was due upgrades to Substation 5.
Ms. O' Brien replied it was not. The drawing setting didn't match the relay setting. It wasn't a
new setting. It wasn't part of an, upgrade. It was a mistake on how it had been labeled originally.
Recent directed testing was performed to catch it.
Page 1 3
Proposed Rate Adjustments (Attachment 3)
RATE
TARIFF No.
Residential Schedule A
MDPU #269
Residential Time -of -Use Schedule A2
MDPU #270
Commercial Schedule C
MDPU #271
Industrial Time -of -Use Schedule I
MDPU #272
School Schedule SCH
MDPU #273
Residential Schedule RW
MDPU #274
Backup and Standby Rate
MDPU #275
Purchase Power, Capacity, and Transmission Charge
MDPU #276
RATE TARIFF No.
Electric Vehicle (EV) Charging Rate MDPU #277
Mr. Seavey from Powerline Models (P.LM) introduced himself, and explained that he is here to
make final recommendations for fiscal year 18 rates.
Mr. Seavey stated that the objectives that RMLD set out to accomplish with the rate design
included adjusting, subsidies between and within classes of customers, ensuring that rates for
large and high -load customers continue
to attract and retain such customers, and ensuring that the rates reflect cost of providing
service. RMLD wants to
provide price signals to encourage customers to reduce demand during peak periods.
Additionally, RMLD wants to protect distribution revenues from erosion due to customer -owned
generation such as solar and battery
storage. The phase-in for some of these changes will occur over time to give customers time to
adjust.
Instead of across-the-board increases, the new rates are meant to adjust for subsidies and move
towards more uniform rates of return. The residential rate of return should increase up to zero
over the next 5 -year period; right now, it's significantly negative. The commercial rate of return
should be reduced from high double digits down to low double digits. The industrial rate of return
will remain where it is; it's low and appropriate for customers of that size.
If the increase was flat across the board to cover expenses and produce the targeted 8 percent
rate of return, residential customers would have had a 5.5 percent increase; commercial would
have had a 5.7 percent increase. Instead, the first year of the 5 -year phase-in is a residential
increase of 6.6 percent. Commercial customers will have a 3.5 percent increase this year. There
will be similar changes each year. However, each year the rates will be revisited. The rate
percentage changes over 5 years are based on projections that we have today regarding
increases in RMLD's operating and maintenance costs and increases in capacity, transmission,
and purchase energy costs.
Mr. Seavey explained the changes to commercial and industrial rates. While industrial and
commercial customers will see an increase, the next few years should show a decrease as
capacity costs change. Rates will be more uniform and fair, but still quite competitive and
attractive, particularly for the commercial and large customers. Another recommendation that
aims to get price signals correct is to phase in a purchase. power capacity transmission (PPCT)
demand charge. In the past, all those costs have been recovered through an energy charge.
That tends to result in a subsidization of poor load factor customers by high load factor
customers. By charging the correct price signal for demand, we remedy that situation and
provide rate relief to customers who use their demand a lot. Only one customer in the first year is
going to see an increase of more than ten percent. With the decreases in the following years no
demand customers will see an increase, even with the phase ins of the demand. This is as
painless a way of doing a significant shift of revenue, from energy to demand charges, as you
can accomplish.
Page 1 4
Proposed Rate Adjustments (Attachment 3)
The renewable generation rate has a subsidization, but it is relatively small. It is $15 or $20
thousand a year for the existing 80 customers. It is more reasonable to cap the total amount of
the subsidy rather than putting a cap on the amount of solar that can be installed. The cap is
significant: $100,000, but only represents a cost to customers of 11 cents a month. It will not
penalize customers who have already made an investment in facilities.
Immediately recommending back up and stand by rate to protect against customers installing
larger amounts of generation, particularly non-renewable generation like back up and stand by
generators or co-generation systems.
Ms. O'Brien clarified that the charge is to protect RMLD and its customers and that she wants
customers to understand what that means. It's to protect everyone because we still pay
distribution charges, we still have to keep the system up and running. RMLD is not trying to
penalize people for putting in solar. We must recover our production charges and we still have
to maintain the electric system.
Mr. Seavey stated that everyone who uses the distribution system supports it appropriately. When
a customer installs generation behind their meter they're continuing to use the distribution
system just as much. The idea is to continue to recover revenues to maintain, own, if you don't,
rates will rise for everyone. That, or you don't earn enough money to cover your expenses and
you don't maintain the system.
Mr. Talbot asked if a customer would still be able to disconnect from RMLD. Ms. O'Brien
answered yes, although it's risky and it's their responsibility. Mr. Talbot asked for the amount of
the standby rate, and clarified that this is
just a recommendation at this point. Mr. Seavey corrected him and explained that the rate is
being filed. The
charge is the present distribution rate times the amount of capacity the customer wants you to
back up. They'll still avoid purchase power, capacity, and fuel charges.
Mr. Talbot asked who would this rate effect right now? Mr. Seavey answered: nobody, but it
should be on the books. Mr. Talbot then asked how many municipals have a back-up and stand
by rate now? Mr. Seavey replied, about half.
Ms. O'Brien explained that there is a strategy behind this rate; when she arrived at RMLD the first
thing she did was unbundle the rates, because she knew this was coming. if large customers are
producing all this power, we still must pay for the distribution system.
Mr. Seavey stated that the residential time of use rate, proposed changes will not work with
RMLD's billing system. Presently the time of use is in the distribution rate and there is no time
varying component, in the distribution charge. It should be in the purchase, capacity, and
transmission charge where you have the on and off peak component. This should be addressed
at some point in future. For now, equal factors were added to on and off peak across the board.
Mr. Talbot asked if that meant those customers won't have as high an increase. Mr. Seavey
explained there is still a high increase because the current rate is too low.
Mr. Seavey continued, stating In 2014 an electric vehicle rate was piloted for the three charging
stations at Analog. Took a look at how that has been working and how the cost has changed.
There is not enough usage data to be conclusive as to whether the existing rate is adequate. He
is proposing a rate that is roughly equivalent to the pilot rate but that the use of the charging
stations is monitored.
There was discussion as to where the best location to place a charging station in Reading would
be. Ms. O' Brien explained that there will be two at RMLD; one is from the grant and we're
getting an electric vehicle. Ms. O' Brien explained RMLD is trying to encourage its employees to
Page 1 5
Proposed Rate Adjustments (Attachment 3)
purchase electric vehicles. Mr. Talbot expressed his reservations that any resident would want to
charge their vehicle at RMLD.
Ms. O'Brien mentioned that RMLD could get into the business of installing electric vehicle
charging stations at people's homes. Braintree has an electric vehicle leasing program. They're
really engaging the community to bring in electric vehicles and putting in charging stations. But,
we're not going to build them and see if customers come. They need to come and we'll build
them.
Mr. Talbot asked what will happen when people are charging during peak times. Ms. Parenteau
explained that the charging stations can be programmed to either shut off or reduce the
amount of electricity being used.
Chairman Pacino stated that he has a procedural question. Why did the Electric Vehicle rate
not go before the CAB before being presented to the Board?
Ms. Parenteau explained that it was an oversight. Rates are scheduled to be effective on July 1,
contingent on being approved at the June 21st CAB meeting.
Mr. O'Rourke asked Mr. Kelley if he had any guidance from a CAB member's perspective. Mr.
Kelley replied that this was his first time seeing the rate; Mr. Talbot has been helpful in giving
insight. However, he needs more detail to understand make an educated decision and thinks
the rest of group will have questions.
Mr. Talbot asked if the Commission can defer this rate tonight. There are no electrical vehicle
stations up yet.
Mr. O'Rourke asked if pulling this piece out of the proposed rates will impact operations. Ms.
Parenteau answered no.
Mr. Talbot stated, as a time of use customer, he pays 6 or 7 cents to charge his car overnight at
his house. He would never use the electric vehicle rate at his job and pay 11 cents. Mr. Talbot
asked how ChargePoint works.
A discussion about how ChargePoint operates and makes its revenue ensued, with Ms.
Parenteau explaining that they get ten percent of sale for processing the credit card payment.
Mr. Talbot added, and we get to use their name and be on their app.
Mr. O'Rourke made a motion, seconded by Vice Chairman Hennessy, that the RMLD Board of
Commissioners approve the rates MDPU numbers #269, 270, 271, 272, 273, 274, 275, and 276,
effective July 1, 2017 on the recommendation of the General Manager.
Motion Carried: 4:0:0.
Chairman Pacino stated that the Commission agreed to hold off on voting on the electric
vehicle rate,motion, and will defer that to a future meeting.
Mr. Kelley asked if Mr. Talbot could make it to the next CAB Meeting; he cannot. Chairman
Pacino will attend.
Power Supply Report - March and April 2017- Ms. Parenteau (Attachment 2)
Ms. Parenteau stated that she will be reporting on the April and May Purchase Power, starting
with kWh sales in the first quarter of 2016 versus 2017. In 2017, 216 million kWh were sold,
compared to 210 million kWh in 2016. Sales were up about 2.88 percent in 2017. However, when
you look at the full fiscal year, it's considerably flat. It's 0.6 percent higher in 2017 than 2016, and
that includes May and June estimated.
Page 1 6
Power Supply Report - March and April 2017- Ms. Parenteau (Attachment 2)
The total revenue received in the first quarter from Purchase Power, Capacity, and Transmission
(PPCT) totaled about $500,000 less in 2017 than 2016. There are two contributing factors related
to this -in 2016 sales were down about 2.6 percent, so we had to recover more dollars over less
kWh. In 2017 we're up about 1 percent. Additionally, in 2016 our revenue in the beginning of the
year was less than our expenses. Over the year, we try to recover the full Purchase ,Power and
Capacity costs. It was necessary to increase PPCT in the 3rd quarter because of that situation. In
2017, revenues were exceeding expenses so that allowed us to decrease PPCT in the third
quarter. Overall, capacity and transmission expenses from 2016 to 2017 increased 5.6 percent or
$1.7 million dollars.
Now that our portfolio contains quite a bit of hydro projects, thought it would be interesting to
look at precipitation and how that relates to the hydro projects. January and April of 2017 had
considerably higher precipitation than in 2016; overall, for the quarter, the average was 3.5
inches compared to 2.6 inches. In 2017, productions were up in January -and April for the hydros
that we have purchase power agreements with.
Natural gas is the commodity that really dictates the spot market. However, the more hydro that
we have, the less we have to buy on the spot market. These projects have been very beneficial
to us within our portfolio.
Financial Report - April 2017 - Ms. Markiewicz (Attachment 4)
Ms. Markiewicz said that she would be reporting on the April 2017 financials, beginning with
accounts receivable.
RMLD is 82 percent current, 15 percent overdue by 30-90 days, and only 3 percent over 90 days
is outstanding.
In FY 16, 89 percent was current, 9 percent was overdue by 30-90 days, and 2 percent was over
90 days. We've improved greatly since FY 15, where we had 75 percent current, 20 percent
overdue by 30-90 days, and 5
percent over 90 days past due. Moratorium ended in April with two big collection pushes, which
we should see
the effects of in May or June.
Vice Chairman Hennessy asked if the percentages were for all customers. Ms. Markiewicz replied
in the affirmative; this is for commercial, residential, and industrial.
Vice Chairman Hennessy asked whether it was residential or commercial customers who
typically owe more. Ms. Parenteau explained that RMLD can shut off commercials for non-
payment. Residential customers have a moratorium protecting them from shut off from
November to April, so it's usually residential who owe more.
Ms. Markiewicz continued, stating that the base revenue as compared to our operating
expenses in fiscal year 2017 year-to-date $21,660,000 in base revenue, compared to fiscal year
2016 of $19,702,000, which is about a 10 percent increase. The 2017 budget was $21,250,000, so
we're slightly above budget; about 1.6 percent. The base revenue compared to our, operating
expenses is on target, with a 10 percent increase as well. Fiscal year 2017 year -to -date -is right on
target: $17,538,00; FY 2016 was $15,915,000. When you compare that to the budget, we're
about 1.4 percent less than anticipated at $17,837,000. Overall, we're right on target'budget-
wise.
Purchase Power, Transmission, and Capacity revenue is $28.2 million, as compared to the
expense of $26.8 million. Fuel revenue was $27.7 million, with a fuel expense of 27.4. The $1.7
million excess in revenue will bring our true net income to $4 million, as compared to last year's
3.6 million. The overall budget is looking at an 18 percent increase. It's important to remember
that there are lots of adjustments on the books at year end. Auditors were in-house yesterday
doing preliminary testing. They were supposed to be here again today, but didn't feel that it was
necessary.
Page 1 7
Engineering and Operations Report - March and April 2017 - Mr. Jaffari (Attachment 5)
Mr. Jaffari stated he would be reporting on March and April 2017. Routine construction year to
date spending is $1,606,613. For fiscal year 2017 $9.5 million has been budgeted for capital
projects. To date, $5.8 million of the budgeted .amount has been spent and a balance of $3.7
million remains. We're going to catch up in June; there's a large payment being made on the
DG project and that will bring expenditures to $9.5 million.
Routine maintenance is on target. Good progress is being made, especially on pole inspections,
transformer replacements, and substation maintenance. There were no hot spots either month.
Double poles are a work in progress.
The reliability indices, SAIDI CAIDI and SAIFI, are measures that show the health and wellbeing of
the system. Our reliability is good. RMLD is well below the national and regional averages..for
outages. Bench markers are set by APPA. We're doing very well. The main outage causes from
2012 to 2017 were equipment, trees, and wildlife. 2017 year-to-date, April had a couple of storms
that brought trees down. Unfortunately, there's nothing that can be done about pine trees that
come down and cause extensive damage to the lines. Equipment outages are shrinking. We're
heading in the right direction.
General Discussion
The next RMLD Board of Commissioners Meeting will be on Thursday, July 20, 2017. The next CAB
meeting is Wednesday, June 21, 2017. Chairman Pacino will attend.
Chairman Pacino stated that since he is signing the AP Warrants for this month he is also
Secretary. He expressed his concern that a lot of minutes need to be approved. Ms. Schultz
agreed, and stated they were on the agenda for the next meeting.
Executive Session
At 9:06 pm, Mr. O'Rourke made a motion, seconded by Vice Chairman Hennessy that the
Commission go. into Executive Session to conduct business in relation to other entities making,
selling or distributing electric power, to consider the purchase of real property, and to discuss
strategy with respect to collective bargaining and return to Regular Session for the sole purpose
of adjournment.
Chairman Pacino called for a Poll of the Vote:
Vice Chairman Hennessy: Aye; Chairman Pacino: Aye; Mr. O'Rourke: Aye; Mr. Talbot: Aye.
Motion Carried: 4:0:0
Adjournment
Mr. O'Rourke made a motion, seconded by Vice Chair Hennessy, to adjourn the Regular Session.
Chairman Pacino called for a Poll of the Vote:
Vice Chairman Hennessy: Aye; Chairman Pacino: Aye; Mr. O'Rourke: Aye; Mr. Talbot: Aye.
A t7/ro
urby
f the RMLD Board of Commissioners minutes
as a majority of the Commission.
ip B: Pacino, Secretary Pro Tem
LD Board of Commissioners
Page 1 8
READING MUNICIPAL
LIGHT DEPARTMENT
BOARD OF COMMISSIONERS
REGULAR SESSION
THURSDAY, JUNE 15, 2017
QUARTERLY UPDATE:
ORGANIZATIONAL & RELIABILTY REPORTS
ATTACHMENT 1
LEIDOS - 201S ORGANIZATIONAL STUDY
Leidos Timeline
Recommendation Not Accepted
RMLD Proposed Timeline
Recommendation Completed
Print date: 6/7/2017 1.
1 of 3
orvisios
-
CONSULTANT RECOMMENDATION
DATION
• ' CY 2015' . &2616CY 2017
43 44. Q1 Q2 Q3 44 .Q1l :Q2 43'
CY 2018 "
RMLD WORKPLAN/COMMENTS
Q4
1
ESTABLISH PLANNING CULTURE
1.1
GM
Update 2008 Strategic Plan (New Strategic Plan)
1.2
GM
Establish planning culture
On-going
1.3
1
Update Integrated, Resources plan
1.4
1.5
GM
EO
Update six-year plan
Develop electric system master plan
Annually
Long-term Planning, GIS, and Technology Roadmap
2
DEVELOP AN EFFECTIVE SUSTAINABLE WORKFORCE
2.1
Develop workforce development plan
Leidos Support; CBA
2.2
Develop succession plans
Leidos Support - CY16 Q2 and Q3; CBA
2.3
2.4
HR
Update job descriptions
Implement consistent performance review process
Leidos Support - CY16 Q2 and Q3; CBA
Leidos Support - CY16 Q2 and Q3; CBA,
2.5
Hire additional HR personnel
on hold
2.6
Increase efforts to fill vacant positions
On-going; evaluating
3
IMPROVE ORGANIZATIONAL EFFECTIVENESS
3.1
Reorganize to better align functions
On-going
3.2
3.3
GM
GM
Create new.Finance and Administration division
Align Customer Services under the Integrated Resources Division
Completed
Completed
3.4
3.5
EO
Reorganize & Expand Engineering group (DeveloSystem Engineering Group)
Formalize business process and performance measurement
Tied to IBEW negotiations. Posted two systems
engineer positions; CBA
Assessing IT roadmap and staffing - near completion.
3.6
Develop and implement internal and external communication plans
Review roadmap.
3.7
4
Assess organizational culture and employee satisfaction
DEVELOP LEADERSHIP CAPABILITIES
Leidos Support
4.1
GM
Assess leadership
Completed
4.2.
Provide management and leadership' training.
On-going
4.3
Provide cross -divisional management training.
On-going
Print date: 6/7/2017 1.
1 of 3
LEIDOS - 2015 ORGANIZATIONAL STUDY
Leidos Timeline
Recommendation Not Accepteo
RMLD Proposed Timeline
Recommendation Completed
Print date: 6/7/2017 2 of 3
CONSULTANT RECOMMENDATION
CY 2015 'CY 2016 .' CY 2017
CY 2018
orvistoro
.
''42':.
RMLD WORK-PLAN/COMMENTS
Q3: Q4..'Ql ::Q2 Q3 '_44. .Q1': Q3 , Q4.
'Ql
5
ESTABLISH PROJECT MANAGEMENT CULTURE
5.1
Develop project management policies and procedures
Competed
5.2,
Establish, project management training plan
SIX MIX
HR to organize with Director of E&O; CBA
5.3
Add project management experience and certifications to job descriptions
On-going - job description revisions; CBA
\
5.4
Establish project management performance expectations
CBA
6
ENSURE COMPETITIVELY PRICED SERVICES
6.1
IR
Continue regular cost of service and rate design review
Performing COS 2017
6.2
IR
Increase customer and engagement and education of alternate rates "
TOU, DSM, Education, Solar Choice
7
IMPROVE FINANCIAL PLANNING AND RISK MANAGEMENT
7.1
B
Review and update reserve policies
S
All policies - steady progress
Integrated Resources
7.2 Establish a risk management committee and enterprise risk management plan. \
7.3
B
Develop a succession plan for the Manager of Accounting and Business
Completed
7.4
B
Formalize financial and accounting business processes
In
progress.
8
STRENGTHEN SAFETY CULTURE
8.1
GM
Review Board Safety Policy
All policies. Developed Safety Program.
8.2
Develop injury and illness prevention program
Review of existing manual and OSHA requirements
9
DIVERSIFY RESOURCES
9.1
IR
Develop distributed generation penetration study
Complete ? DSM and max/feeder?
9.2
Review cost effectiveness and economic potential for end-use measures
Tangent and DSM
10
ESTABLISH A CULTURE OF COMPLIANCE
10.1
Assign Compliance Manager and develop compliance plan and requirements.
Leidos Support
11
IMPROVE CUSTOMER SERVICE
11.1
IR
Conduct customer satisfaction surveys.
Communication Plan
Print date: 6/7/2017 2 of 3
LEIDOS - 2015 ORGANIZATIONAL STUDY
Leidos Timeline
Recommendation Not Accepted
RMLD Proposed Timeline
Recommendation Completed
DIVISION
CONSULTANT RECOMMENDATION'
' CY 2015 CY 2016 CY 2017-- �CY.2018, '
RMLD WORK-PLAN/COMMENTS
Q3 44. :Ql QZ' Q3' 44 Q1,'Q2 Q4 Q1 QZ
11.2 IR
Conduct post transaction surveys.
log Communication Plan
11.3 IR
Develop and implement customer engagement plan.
Service Requirements Handbook completed. Issued
new Terms and Conaitions. Constant Contact -17,000
emailaddresses
12
PLAN FOR FUTURE TECHNOLOGIES
12.1 1
Complete operating technology roadmap
13
FOCUS ON ASSET MANAGEMENT
13.1
Develop and implement an asset management plan
Asset Management System - GIS/Cogsdale
13.2
Develop and implement asset management business processes
13.3
Implement asset management system
13.4 IR
Develop customer service manual (Service Requirement Handbook)
Completed
14
LEVERAGE GEOGRAPHIC INFORMATION SYSTEMS
14.1 EO
Conduct robust GPS -based inventory of assets and Infrastructure
CDM - on-going
14.2
Adapt and implement industry standard common.information model
CDM - on-going
14.3 EO
Develop and implement business processes for GIS management
CDM- on-going
14.4 EO
Provide GIS training for Engineering and Operations (Add Other Divisions)
On-going
15
FORMALIZE AND ENHANCE WORK MANAGEMENT
-
15.1
Develop work management business processes
Integrated with asset management plan: SpryPoint
15.2
Implement modern work management system
Completed
16
PLAN FOR RESILIENCY
16.1
Develop disaster recovery and business continuity plans
Emergency OP Procedure - completed.
17
ENHANCE FACILITIES
17.1
Enhance current workspace
On-going - carpet, gym, paint, reorganize office space
Print date: 6/7/2017 3 of 3
BOOTH AND ASSOCIATES - 2015 RELIABILITY STUDY - RECOMMENDATIONS
•
-
.
RECOMMENDATION
CONSULTANT RECOMMENDATION
YEAR
COST (Booth Estimate) -;
urrnxetr
RMLD,WORKPLAN
_
"
•
, x
SOLUTION
=..STATUS' -
_
.. -
1
BOOTH
Replace cable trench covers at Sub 4 (should be expense, but most put large investments
"
in capital)
2015-16
$100,000
✓'
`completed
- _ -
2.1
2
BOOTH
Sub 5 bus duct from transformer to switchgear has reached the end of useful life and
2015-16
$400,000
V'
Bus 0 ahtl`E semp
• etions.to the transformers m .leted11/12/16 on .' Main Bus 0and E sections,
should be replaced with the switchgear replacement
^
completed
P
to be reinsulatedstartingthe'week of2/27/2017, . _
-�
3
BOOTH
Replace fence at Sub 4 and Rx grounding issues.
2015-16
.$100,000 ,
, , ✓
.� _
• completed
- -
4
BOOTH
Rebuild pole line along Lowell Street - -.
2015-16
$375,000
completed".
^. -,. • .'' - -'
' 5
BOOTH
Complete AMI Upgrade and RF Mesh Network
2015-16
$350,000
✓
in
_''
Fve gateways mstalled:�Relays installed Additional•meters in stock. Working on '
-
_
,' -
progress
communicating issue:with 1'deployed•meter. -°
6
BOOTH
Implement GIS Upgrade Program
2015-16
$350,000 - $750,000 -
✓
_in progress
_
GIS asset survey is in-progresi
7
BOOTH
Implement Arc Flash Study Analysis
2015-16.
$30,000 _✓'
completed,
- - -
8
BOOTH
Develop construction standards
2015-16
in-house
✓
in;progress.
'
'9
BOOTH
Update Joint -Use Agreement with Verizon
2015-16
in-house
✓
•'- '.:'
in progress',-•��
_ _
10
BOOTH
Replace bushings on Sub 4 transformer. .:
20.15-16
- $150,000
` .. ._
completed
Cr wiring at Sub 3 should be fixed. The CT circuits_ should only be bonded on grounding in
11
BOOTH
exactly one spot
2015-16
- ow
✓
completed,.",
CT's are grounded in only one location.:
12
BOOTH
Sub 3 has NO under -frequency trips. Relay is not programmed to trip.
2015-16
0&M.
✓
compiefed
Station 3<fias 11F capability. RMLD is in comPllance,with ISO's OF requirement; -
Fence grounding is not up to code@ Station 4. Fabric and barbed wire should be
13
BOOTH
.
grounded.
2015-16
0&M
', '✓
-
completed
I . .. ... _ .. ,
14
BOOTH
Earth/gravel around fence at Sub 5 -
2015-16
O&M r
✓
.'
completed
' ' - -• - -
- 15
BOOTH
Interface CIS with GIS platform -
2015-16
in-house °,
_✓
" " •
in progress-,,'
GIS Data collection ii in;progmss •• - - '
16
BOOTH
Create Milsoh Windmil' model
2015-16
in-house '
_'
�. ✓
Being done ii coniuc(ionwith GIS mllecuon: As each feederis;mmpleted by,DRG±tis being
in.
progress
'
sent to Milsoft'to create the model.
17
BOOTH
Complete SCADA software and hardware upgrade
2015-17
$350,000
✓
• in progress: -
nbimensions,cyber'securiry software complete. -
18
BOOTH
Upgrade main feeder of Circuit 5W9 to 795 to address voltage and conductor capacity '
✓:
The first 3000' has been -reconductored. This work can only be,done during the fall/winter,
Issues (1.6 miles)
2015-17
$240,000
...
in progress
months. May.have arhurdle.with,Verizon and pole. replacements.
-"
Can't -parallel up the feeder get a ways,at Station 4 and Station S, no spareconduits available.
19 (1)
BOOTH -
Upgrade UG circuit 3W5,3W13,4W9,3Wib,4W14,4W36,4W23,4W24,4W28,4W30,
2015-19
- $850,000..
✓
3
-
Cant arallely [he feeder eta-awa sat Station=3; roomfor'.the second set of cablesih:
P F - 6 no y.
SW4 exits to parallel 750 Cu .. -
- -
the back of-the;switchgeaC Solution: Load reliehby feeder switching and/or new Wilmington'.
I
Substation.
20
BOOTH
Replace breakers at Sub 4 due to age and condition
2015-20
$3,000,000 "
✓
completed'
All 2&break_ers were;replaced�by'1/30/2016,..
Pole inspection and replacement program. RMLD currently Inspects 10% of RMLD-owned.
..
,. ,. ' • -
21
.
BOOTH
poles per year. Negotiate with Verizon to address Verizon -owned poles. Total 13,000
P
2015-24
$9,000,000✓•'
-in:progress:, ,
_
2014 /2035x/2016 ±nsp'ection completetl Pole replacement in- progress
poles.
,
22
BOOTH-
Continued implementation of Grid Modernization Plan (GMP)-
2015-24
'•
• Outage Management (OMS)
• '
`in
OMS installed waiting'forGIS overhaul. and AMI lntii ation"
$100,000
.✓
progress
-
-
Transformer Loading Management TLM
8 8 ( 1
$100,000 �
✓
-
in. progress
' ' •' - - - - -
'
• Demand Response (DR)
$Soo,000
✓
- ,:
_ in, progress
Demand Side management (DSM)
$100,000
In
_
'
Distributed Generation Program
- $11,000,000
_ ✓'
.: ,•
inprogress'
,,- ,•- . - ` -
23 (1)
BOOTH
Upgrade UG circuit exit 4W7 to parallel 750 Cu
2016
$70,000
-
Cant parallel. up the feeder get-a-way,at Station 4, no spare.condurts available.•Soiution:Load
r
-
reliefby,feeder.switching:and/ornew Wilmington'Substation. .
-
Upgrade main feeder for Circuit SIAS to 795 to address voltage and conductor capacity
'
:r_t'
24
BOOTH
issues (2.5 miles)
2016-17
$375,000
,
Chan a- constructi n yearo FY17" , FY18 and F"Y19: H'u' rde: Verizon poie re lacemeritaea ^'
Print date: 6/7/2017
1 of4
Print date: 6/7/2017 2 of 4
RECOMMENDATION
CONSULTANT RECOMMENDATION
YEAR
COST (Booth Estimate)
RMLD WORK PLAN
AITERNAIE
AccEPiEO
sclimAl
o.
STATUS
25
BOOTH
New Wilmington Substation (land acquisition and design)
201617
$750,000
✓
in progress
Searching for land in Wilmington
Upgrade mato feeder of Circuit 4W24 to 795 to address voltage and conductor capacity
26
BOOTH
issues (1.5 miles)
2016.17
$225,000
.✓
Change construction years. to FY17, FY18'and FY19. Hurdle: Verizon pole, replacement area
27
BOOTH
Complete comprehensive distribution system analysis upon GIS completion
2016-17
in-house
✓
28
BOOTH
Complete the 4 kV Conversion Program
2016-19
$1,500,000
✓
in progress
Change completion date to FY20. Multiple year project. 32+/. stepdown. areas in the service
territory. Converted the Burrough's Road area October 22, 2035.
Sub 3 does have SEL relays but they are all legacy models that don't provide the function
29
BOOTH
(especially communication) of today's versions. If the plan is to have a fully -automated
2016-19
$200,000
✓
in
PLM design complete:. Materials received. Construction in progress: Approximately 70%'
-
system then: replace the SEL relays with the modern version. Should be able to replace in
Ys P Y P
progress.
complete.:
existing hole and wiring..
30
BOOTH
New Wilmington Substation (procurement, design, construction and commission)
2017-19
$4,250,000
✓
in. progress
Searching for land near 115 kV lines in Ballardvale/Upton. Rd area
Sub 5 Switchgear is at the end of useful life. The relaying needs to be updated for the
31(1)
BOOTH
system automation project. The existing breakers are 2008 vintage but should not be
2017.19
$1,200,000
,/
As part of the planning for the proposed substation. in Willmington the need for the
reused. They can be sold on the open market.
Wildwood Substation will be reviewed.
Can't parallel up the feeder get -a -ways at Station 4: and. Station 5, no spare conduits available.
32 (1)
BOOTH
Upgrade UG circuit exits 3W7, 4W5, 5W5, 5W9 to parallel 750 Cu to increase circuit
2017-19
$280,000
✓
Can't parallel up the feeder get-a-aways, at Station 3, no room for the second set cables in
capacity
the back of the switchgear: Solution: load relief by feeder switching and/or new Wilmington
Substation.
33
BOOTH
Feeder Automation - complete System Coordination Study in conjunction
2017-24
$4,000,000
✓
in planning
Upgrade main feeder of Circuit 4W28 to 1000 Cu to address voltage and conductor
4W28 is the dedicated circuit for Analog Devices. Any type of load relief for feeder4W28 will
34
BOOTH
capacity issues (0.3 miles)
2018
$60,000
✓
require the reconfiguration of ADI distribution system or an additional RMLD feeder to the
site.
35
BOOTH
Substation automation
2019
$112,000
- ✓
in progress
Can't parallel up the feeder get-a-waysat Station 4 and Station 5, no spare conduits available.
36 (1)
BOOTH
Upgrade UG circuit exits 4W6, 5W8 to parallel 750 to increase circuit capacity.
2019
$120,000
V
Can't parallel up the feeder get-a-aways at Station 3, no room for the second set of cables in.
the back of theswitchgear. Solution: Load relief by feeder switching and/or new Wilmington
Substation.
Upgrade main feeder of Circuit 4W23 to 795 to address voltage and conductor capacity
37
BOOTH
issues (1.1 miles)
2020
$165,000
✓
Change construction years to'FY20, FV21 and FY 22. Hurdle: Verizon pole replacement area.
Can't parallel up the feeder get-a-waysat Station 4 and Station 5, no spare conduits available.
38 (1)
BOOTH
Upgrade UG circuit exits 3W18, 4W4, 4W10, 4W18 to parallel 750 to increase circuit
2021.23
$370,000
Can't parallel up the feeder get-a•aways. at Station 3, no room for the second set ofcables in
capacity.
P tY,
the back of the switchgear. Solution: . Load relief by feeder switching and/or new Wilmington
Substation.
Upgrade main feeder of Circuit 4W9 to 795 to address voltage and conductor capacity
39
BOOTH
issues.
2021-23
$75,000
✓
40
BOOTH
Review and upgrade electric. system comprehensive analysis
2024
$100,000
✓
Transformer D and E replacement at both Sub 4 and Sub 5. They are approaching their
41
BOOTH
end of useful life.
2024-25
$3,400,000
✓
42
BOOTH
Install oil containment for Transformer D and E at Sub 4
2024.25
$100,000
✓
completed
Can't parallel up the feeder get-a-waysat Station 4, no spare conduits available. Can't parallel
43(l)
BOOTH
Upgrade UG circuit exits 3WB, 4W12 to parallel 750 Cu to increase circuit capacity.
2024.26
$180,000
✓
up the feeder get-a-aways at Station 3, no room for the second set of cables in the back of
the switchgear. Solution: Load relief by feeder switching and/or new Wilmington Substation.
Print date: 6/7/2017 2 of 4
Print date: 6/7/2017
3 of
'
RECOMMENDATIONAETEenAiE
' ` • -' `
CONSULTANT RECOMMENDATION
YEAR
COST (Booth Estimate(
_
RMLD WORK PLAN
"A(CEPTEO
SOLUTION
STATUS.
44
BOOTH '
Upgrade main feeder of Circuit 4W30 to 795 to address voltage and conductor capacity
•
issues.
2024-26
5165,000
'✓
,
- ..
-
45
BOOTH
Replace control panels for Ring bus at Sub 4
2024-26
5200,000
✓
'completed -
Design Complete: Material to arrive°by 10/24/16. Construction'100%completed.
Completion In early March 2017.. -
46
UPG
Station 3 Transformers: 113. Adjust timingdela on the winding temperature tri
Y g P P•
V
-
-
in progress
PLM designing upgrades: Materials out: to bid September 2016; award'pending. Construction
to oegign mid March 2017.
47
UPG
Station 3 Transformers: #4. Add a low oil trip to transformers so they trip before any
✓
PLMdesi nin a rades. Materials out'to.bid September 2016; award end n Construction
6 B P8 P P 8•.
winding damage can occur.
in progress
p g
t0 begin in mid March"2017.
48
UPG
Station 3 Transformers: #5. Replace LTC main braking rollers with the new design that has
-
•. - .' ..
a brass sleeve for the roller to ride on.
✓
completed
Scheduled.forlate November 201,6 Rollers replaced on 12/2/2016
49
UPG
Station 3 Transformers: 96. Repair LTC control displays for #TA and #TB
✓
completed•
LTC controls repair and installed:
50
UPG
Station 3 Transformers: 117. Replace or repair the Trans-TB Hydran unit.
,[
-
51
UPG
Station 3 Transformers: #8. Repair the Trans TB temperature differential unit which is in
failure mode.
s/.
-
completed
Unit replaced.
52
UPG
Station 3 15 kV Breakers 112: the close spring assembly needs to be replaced.
✓
-
-in progress
- -
53
UPG
Station 15 kV Breakers: #3. OC control power fuses for trip, close, motor should be
in
Will. be addressed during Station #3 upgra des'Ma[erials have'bee received. Construction to,
separated. .
s/
-
•✓
progress
begin in Mid March 201.7. -
54
UPG
Station 3 15 kV Breakers: #4. Control handle trip should be separated from relay and
-
Will be. addressed during Station 03 upgrades Materials have bee received: Construction to
should trip breaker directly.
in progress•
-
begin in Mid•March 2017. -
55
UPG
Station 3 Relays: #1. The DC negative feed to the differential relay for the digital inputs
- ✓.
in
Will-be addressed during Station 03 upgrades Materials have'bee received. Construction,to,
should be altered to tie a DC negative via a fuse.
progress
-
begin.in.Mid March-2017.
56
UPG
Station 3 Relays: 02. Review and alter the under voltage transfer scheme so that it
Will'be addressed during Station #3'upgrades Materials have,bee received. Construction to"
operates like the same schemes at the other stations.
ih•progress
begin In Mid March 2017.
57
UPG
Station 4 115 kV Breakers: 01 (GCB1). Replace the breaker.
,/'-
completed
_
- -
58
UPG
Station 4 Transformers: #1. Repair trans 4110D cooling contactor for stage #2.
Will need to follow-up with UPG for`more information.
59
UPG
Station 4 Transformers: 142. Replace the trans #110D main tank pressure relief device
contact.
�/ .
'
n'
completed
'
- -. -
60
UPG
Station 4 Transformers: 93. Replace the trans #110D main tank low oil gauge.
✓
-
completed
- - -
61
UPG
Station 4 Transformers: 94. Repair the DC control power supply control cabling.
-
✓
completed
- -
Station 4 Transformers: #5. Replace the trans 110E main tank low oil and pressure relief
,✓
62
UPG
device cables from the devices to the conduit bodies.
completed
.. "
63
UPG
Station 4 Transformers: 46. Replace the trans 110E cooling fan mounted top left.✓"
-
•completed •
_ -
64
UPG
Station 4 Transformers: 07. Replace all four bushings of Trans #110E and #110D.
✓
'completed ,
See,ltem #10 (Booth` Recommendation)
Station 4 I5kV Breakers: 112. check circuit 4W11 on a normal basis to insure that the
65
UPG
heaters remain on to keep the breakers above ambient temperature so that no moisture
✓
-
completed
- -
condenses on the breaker insulation.
66
UPG
Station 4 Breakers: 04. Replace the ground stab on 4W22.
✓
•completed .
Station 5 Transformers: #1. Replace the trans #D main tank low oil and pressure relief
67
UPG
divide output cable. Reconnect the LTC low oil level gauge wiring in the conduit body
completed'-
where the device cable terminates.
68
UPG
Station 5 15kV Breakers: #1. Take bus out of service and check alignment and correct if
-
Bus D and E sectlonsto the transformers completed on 11/12/16. Main Bus D andsections'
possible.
•
tom leted
P
_E
to be reinsulated starting the week of 2/27/2017. ,
Print date: 6/7/2017
3 of
'`7r+4*,l"0171",i
..414•'' )�-M�'d ..�i%4. �t�-d'-::, T
2
G• CONSULTANTRECOMMENDATION
*tveaRe
r r..:
eosr(B
ottfEstimaieL
". RECOMMENDATION
; . - Rf1ALD_ WORK PLAN: -
'A Pita
.urtnunTe .
.. ....
STATUS
xk.'"...lF• .sr't.A'
v
SOCUnON
' _
69
UPG
Station 5 15kV Breakers: q2. Remove breaker 5W9, inspect for corossions, and correct
" .�
-
Bus D and E sections to'the transformers completed on 11/12/16: Main Bus D,and E sections'
misalignment of the Breaker contact Rosette and cell stab during maintenance cycle.
B g cY
- completed_ ,
•.
to be reinsulated starting the week of2/27/2017.. -
70
UPG
Stations ISkV Breakers: p3. Take bus out of service and check alignment and correct if
' -'�
Bus D and E sechonsto the. transformers,completed on 11/12%16. Main Bus D and E sections
possible.
P �
-
Completed
tobe reinsulated starting the week of 2/27/2017.-
2017. - -
71
UPG
UPG
Station 5,15kV Breakers: p4. Take bus tie breaker out of service and check alignment and
-.
� �.
Bus D and E sections to the transformers completed on 11/12/16. Main BusD"and E sec ions,
correct if possible.
P
Completed„
.
- - •: - -
to be'reinsulateds[arting the week of
Necommenaoons ano priorities are oasea on existing system conditions. Should conditions change, these priorities will likely require re-
evaluation.
(1) New Substation in Wilmington will address these recommendations: alternate solution provided in the meantime.
Print date: 6/7/2017 4 of 4
POWER SUPPLY REPORT
MARCH & APRIL 2017
ATTACHMENT 2
Integrated R.eso
RMLD Board of Commi!
Reporting
Jane Parenteau
Director of Integrated Resources
kWh Sales
1st Quarter 2016 vs. 2017
AW -44W
January _ February�� March April I Q1 Total j
48,836,336 54,279,229 52,417,738 55,283,094 210,816,397
®
2017
17 56,812,248 1 57,075,866 52,281,239 50,728,215 216,897,568
®2016 ■2017
Purchase Power, Capacity and Transmission (PPCT) ReVE
1 It Quarter 2016 vs 2017
--;_-_--- -- January. -----4- .-- . Februa_ry March April . Q1. Totals
m2016 $2,075,758 $2,712,157 _ 4 -'
— - --
_- � _ - $2,894,687_ - -$3,106,977 i-- $10,789,579 i
■2017, $2,846,098 - $2,740,693 __.
$2,444,474 i $2,261,244 $10,292,509
Capacity, Transmission
January -April
201
Precipitation by Inches
Reading, MA
2016 vs. 2017
1St Quarter
January February March j April P Averages
—2016-2.71 2.59 3.36 2.07 2.68
20171 4.44 0.07 1.69 7.74 3.49
—2016 —2017
Hydro Pr(
1St Quartet
2016 vs. 21
7,000,000
6,000,000
5,000,000
r
3 4,000,000
Y
3,000,000
2,000,000
1,000,000
c
Precipitation Levels and Their Effects on Energy Produc
1 St Quarter 2016
16,000,000
14,000,000
12,000,000
r
3
Y
c 10,000,000
0
v
�0 8,000,000
0
n`.
o,n 6,000,000
c
w
4,000,000
2,000,000
0
January February March April
Hydro Spot Market -Precipitation
j
10.0c
9.00
8.00
7.00
6.00
5.00
4.00
3.00
2.00
1.00
0.00
Precipitation Levels and Their Effects on Energy Produc
1 St Quarter 2017
16,000,000
14,000,000
12,000,000
s
0 10.000,000
V
0 8,000,000
CL
6,000,000
a,
w 4,000,000
2,000,000
0
January February March April
9.00
8.00
7.00 ,,,
m
L
6.00
C
5.00
C
4.00
Y
3.00 'n
v
2.00 a
1.00
0.00
Hydro Spot Market -Precipitation
PROPOSED RATE ADJUSTMENTS
ATTACHMENT 3
necutc. Kate:- uesig
Recommendations
Reading— Munjcipal Light Department
P L M Electric Power Engineering
Strategic Rate Design Objectives - -
• Reduce -or eliminate subsidies betinreen. and within classes of
customers
• Ensure that rates for large, high load factor customers can
attract and retain such. customers
• Make rates more reflective of the cost of providing service
Provide price signals that: encourage customers to reduce
demand during peak periods and to increase usage during off-
peak periods
Phase-in changes over period of time to permit: customers -time
to respond and. -adjust
Protect distribution revenues from erosion due to customer -
owned generation of electricity.
June 15, 2017 PLM Electric Power Engineering
2
RECOMMENDATION.
Phase 1 n: Scenario -.-3 .Ove.r-.5. - Years
-Instead -of-i-ncreases --of between- 51/2 and 61/2 percent,
average bills would change by the -following
percentages In FY18:
3
Scenario 1
Scenario 3
Uniform
Increase
Move to Uniform ROR
•- Residentia.l
5.6%
-6.6%
• Residential TOU
5.7%
7.6%
• Schoo.1
6.5%
4.7%
i
• Commercial
5.7%
3:5%
Industrial' '
6.0%
'6.1%0
3
Phase -In of Scenario 3 Rate Changes
Average Customer Bri1.1 Impact
10.0%
8.0%
6.0%
2.0% — ----- ---
0.0%
FY18 FY19, • MY120 MY2 FN
-2.0%
-4.0%---
-6.0%- N Residential M Commercial, ®_Industria!_______._____
June 15, 2017 PLM Electric Power Engineering 4
. r r:♦r. r-. r. t� ..rn.+we.:♦4'x.n �.r. .ru ... 1r <. fr �r, w0.r .• .. .r, Ak ir.a.r. '.r:a Fi .r,i n fn .. .4.ir n a....
Phase -In of Scenario 3 Rate. Changes
Average, -Customer Bill I.m-pact
Residential 750 kWh
$140 ------------------------- .------------- ..___...-_-_-_....__.___.._-d.__-w___-,_
$120
$100
$60
$40
$20
FY17
June 15, 2017
FY18 FY19 FY20 FY21 FY22
PLM Electric Power Engineering
■ Purchased Power.
fm Energy
■ Base.Rate
5
Phase -I n of Scenario 3 Rate Changes
Average Customer Bill Impact
$9,000 -
$8,000
$7,000
$6,000
$5,000
$4,000
$3,000
$2,000
$1,000
Medium Commercial
FY17 FY18 FY19 TY20 FY21
June 15, 2017 PLM Electric Power Engineering
FY22
■ Purchased Power
Im Energy
■ Base Rate
Phase-Iof Scenario 3 Rate -Changes
Average Customer. Bill Impact
Medium Industrial .
$90,000---------------------------------------------------------------------------------------------------
$80,000
$70;000
$60;000
$50,000
.$40,000
$30,000
$20,000
$10,000
FY17
June 15, 2017
FY18 FY19, FY20 FY21 FY22
PLM Electric Power Engineering
■ Purchased Power
IN Energy
■ Base Rate
7
RECOMMENDATION:
Renewable,- Generation. Rate
• Cap the total a -mount of Renewable Generation:: Subsidy, at - --
$100,.000.per year.
• Represents approximately 300 additional residential solar.
customers
• 'Represents a subsidy cost to an average residential; customer of
$0:41/month , .
• When ,the cap is reached implement one of the three options
identified previously, depending on the cost and availability of
metering and billing:
• Immediately put in place a Backup and: Standby rate to recover
e ,
distribution revenue, requirements from any customer using
energy storage to offset most of all kWh purchased from RMLD
•
Phase-in the elimination of -the- time -of -use
Distribution energy charge and replace with flat rate
energy charge
Phase-in an on -peak and off-peak Purchased
Capacity and Transmission charge to recover most
allocated costs during on -peak hours only
Phase in an annual increase in the Distribution -
Charge over five- years to produce a zero rate of
return- comparable to the -base Residential rate
Phase- in the on -peak Purchased Capacityand
Transmission charge over five years
June 15, 2017 PLM Electric Power Engineering 10
RECOMMENDATION: __
- Electric- Vehicle Rate:
---.Replace'
the existing Pilot 'rate created -in-, 2014with a
tariff filed with the DPU.
• Rate structure:
Distribution Charge $0.1111
-Fuel Charge - - as billed
- Purchased Power Charge as billed.-
- Rate calculation makes assumptions regarding the
level of usage and should be re-evaluated- after
actual usage data is gathered
• Price is equivalent to about $1.80/gallon' of gasoline
June 15, 2017 PLM Electric Power Engineering 11
Town of Reading, Massachusetts
Municipal Light Department
Designation:
Residential A Rate
MDPU # 269 supersedes
and cancels MDPU # 259
Residential Schedule A Rate
Available in:
Reading, Lynnfield Center, North Reading,, and Wilmington
Applicable to:
Individual residential customers far all domestic uses where service is taken through. one
meter. incidental commercial use, not exceeding 20% of the total energy used on the same
premises is permitted.
Character of service:
A.C. 60 cycles: single phase.
Customer Charge:
$4.81 per month
Distribution Energy Charge:
5.06301 per Kilowatt-hour for all Kilowatt-hours usage
Budget Billing:
The customers under this rate will have available to theni a budget billing program under
which the customer is required to pay a levelized amount to the Department each billing
period during the calendar year. The specifics of this program are outlined in the
Department's General Terms and Conditions.
Low Income Discount
The Customer Charge- under this rate will be waived upon verification ofa low-income
customer's receipt of any means -tested public benefit, or verification of eligibility for the
low-income honle energy assistance program, or its Successorprogratll, Ibr which
eligibility does riot exceed 200 percent of the federal. poverty level based on a
110USellold's gross i.nconlc. In a program year in which maximum eligibility 11or LII IFAP
exceeds 200 percent of the federal poverty level, a household that is income eligible
under LIHEAP shall be eligible liar the low-income electric discount. It is the
responsibility of the customer to annually certify, by lornls provided by the utility, the
C011t►l]Ucd compliance with the foregoing qualifications.
Rate Filed: June 19, 2017
Effective: On Billings on or After.luly 1, 2017
Filed By: Coleen M. O'Brien, General Manager
Town of Reading, Massachusetts
Municipal Light Department
MDPU # 269 supersedes
and cancels MDPU # 259
Residential Schedule A Rate (cont'd)
Farm Discount:
Customers who meet the eligibility retjuirements set forth by the Massachusetts
Department of food and. Agriculture for being engaged in the business of agriculture or
fanning, and upon certification to the RMC.I).by the ivlassachusetts Department of food
and Agriculture; will be eligible for an additional 10% discount, prior to the RMLD
prompt payment discount, on rates and charges applicable oil their monthly billing
statement.
Energy Conservation Charge:
The bill for service hereunder may be increased or decreased as provided by the Energy
Conservation Charge.
Fuel Adjustment:
The bill 1'cir service' hereunder may be increased or decreased as provided by the Standard
Fuel Adjustment Clause.
Purchase Power Capacity and Transmission Charge:
The bill for service hereunder may be increased or decreased as provided by the Purchase
Power -Capacity and Transmission Charge.
Mcter Reading and Billing:
Bills under this schedule will be rendered monthly. A prompt payment discount of 15%
will be allowed on the CLIStolllet' Charge and Distribution Energy Charge, only ifthe
entire bill is paid-iri-full by the discount due date.
General Terms.and Conditions:
Service hereunder is. subject to. the General Ternls and Conditions which are incorporated
herein and are a part of this rate schedule.
Rate Filed: June 19, 2017
Effective: On Billings on or After July 1, 2017
Filed By: Coleen M. O'Brien, General Manager
Town of Reading, Massachusetts
Municipal Light Department
MDPU # 270 supersedes.
and cancels.MDPU # 261
Residential Time -of Use Schedule A2 hate
Designation:
ResidentialTime-or-Use A2 Rate
Available in:
Reading, l..ynnlield Center, North heading,, and Wilmington
Applicable to:
Individual residential customers for all domestic uses where service is taken through one
On -'Peak and Oft -Peak meter. Incidental commercial use, not exceeding 20% of the total
energy used on the same premises is permitted..
Character of service:
A.C. 60 cycles: single phase.
Customer Charge:.
$7.44 per month.
Distribution Energy Charge:
$.09450 per Kilowatt-hour for all Kilowatt-hours usage d U ri ng. t he- On -Peak hours.
$,02188 per Kilowatt-hour for all Kilowatt-hours usage during the Off-peak hours.
Definition of Periods:
The On -Peak period is defined as the hours. between'] 2:00 Noon and 7:.00 P.M.. Monday
through Friday except holidays as 'listed under the "Granted Holidays" paragraph listed
below. The Off -Peak period is. (lei ined as the !yours between 7.:00 P.M. and 12:0.0 Noon
Monday .through Friday and all hours Saturday, Sunday and granted holidays' as listed
below.
Contry)lled Water Heater Allowance:
When.a customer regularly uses an electric water heater oi'a type approved by the
Department, 333 kWh will be credited to usage during the Oft' -Peak period and will be
billed at $.00300 per kWli. All kWh used Off=Peak above 33 3 kWli will be charged at
the regular Off=Peak rate. If less than 333 kWh are. used 011' Peak then onl.y.that amount
of kWh will be billed at $.00300 per kWh. Water heater with two elements shall be
interlocked to prevent simultaneous operation. Service to the water heater will be
controlled by a Department owned time.switch in an approved outdoor socket.
Term:
A customer electing to be billed under this rate must remain. on this rate for a minimtun
of one year. At the end of one. year on this rate a customer may elect to remain on. this
rate or be billed under the Residential A Rate.
Rate Filed: .lune 19,2017
Effective: On Billings on or After Jul), 1, 2017
Filed By: Coleen M. O'Brien, General Manager
Town of Reading, Massachusetts
_Municipal Light Department
MDPU # 270 -supersedes
and cancels MDPU # 261
Residential Time-of=Use Schedule A2 Rate (cont'd)
Budget Billing:
The customers under this rate wilt have available to thele a budget billing program under
which the customer is required to pay a ICVeli%Cil a111011nt to the Department each billing
period during the calendar year. The specifies of this program are outlined in the
Department's General Terms and Conditions.
LoNv Income Discount
The Customer Charge under this rate will be waived upon verification ol'a low-income
customer's receipt of any means -tested public benefit, or verification of eligibility for the
lout -income home energy assistance program, or its successor program, for which
eligibility does not exceed 200 percent of the federal poverty level based on a
household's gross income. In a program year in which maximum eligibility ibr L:IHEAP
exceeds 200 percent ol'the federal poverty level, a household that is income eli"ible
under LiHE:AI' shall be eligible for the low-income electric discount. It is the
responsibility of the customer to annually certify, by forms provided by the utility, the-
continued compliance with the foregoing qualifications.
Farm Discount:
Customers who meet the eligibility requirements. set forth by the Massachusetts
Department of Food and Agriculture liar being engaged in the business of'agriculture or
farming, and upon certification to the RMLD by the Massachusetts Department of Food
and Agriculture, Will. be eligible ('or an additional ten percent discount, prior to the
RMLD prompt payment discount, on. rates and charges applicable on their monthly
billing statement.
Energy Conservation Charge:
The bill for service hereunder may be increased or decreased as provided by the Energy
Conservation Charge.
Fuel Adjustment:
The bill for service hereunder may be increased or decreased as provided by the Siandard
Fuel Adjustnlent. Clause.
Purchase Power Capacity and Transmission Charge:
The bill for service hereunder may be increased or decreased as provided by the Purchase
Power Capacity and Transmission Charge,
Meter Beading and Billing:.
Bills under this schedule will be rendered monthly. A prompt payment.discount of 151A
will be allowed on the Customer Charoe, Distribution Demand Charge -and Distribution
Energy Charge, only if the entire bill is paid -in -fun I by the discount due. date.
Rate Filed: June 19, 2017
Effective: On Billings on or After July 1, 2017
Filed By: Coleen M. O'Brien, General Manager
'Town of Reading, Massachusetts
Municipal Light Department
MDPU # 270 supersedes
and cancels NIDPU # 261
Residential Time -of -Use Schedule A2 Rete (cont'd)
Granted Holidays
Under the Residential Time-of=Use Schedule A2 Rate the holidays granted for Off -Peak
are: New Year's Day, President's Day, Memorial' Day, Independence Day, Labor Day,
'thanksgiving Day, Columbus Day, Veteran's Day and Christmas Day.
General Terms and .Conditions:
Service hereunder is subject to the General Terms and Conditions Nvhich are incorporated
herein and .are a part of this rate schedule.
Rate riled: June 19, 2017
Effective: On Billings on or After July 1, 2017
Filed By: Colecu NI. O'Brien, General Manager
Town of Reading, Massachusetts MDPU # 271.supersedes
Municipal Light Department and cancels MDPU # 262
Commercial Schedule C Rate
Designation:
Commercial C Rate
Available in:
Reading, Lynntield Center,'North Reading, and Wilmington
Applicable to:
Service tinder this rate is available to industrial or commercial customers who take all
their requirements under this rate. All electricity (urnis}ted Wider this rate will be metzred
through one service finless it is convenient for the Department to du otherwise.
Character of service:
AC 60 cycles: single phase or three phase.
Customer Charge:
$7.4.7 per month.
Distribution Demand Charge:
$7.82 per Kilowattfor all demand Usage.
Distribution Energy Charge:
�.01659 per Kilowatt-hour for all Kilowatt-hours usage.
Budget Billing:
The eftstomers under the C Rate may elect the BudgCt Billing program under which the
Customer is required to pay the levelized amount to the Department each billing period
during the calendar year. This rate is not available to C Rate Customers electing the
Contract Demand Rate, or the Non -Firm Demand Rate. The specifics ol'thns program -are
outlined in the Department's General Terms and Conditions.
Energy Conservation Charge:
The bill for service hereunder may be increased or decreased as provided by the Energy
Conservation Charge.
Fuel Adjustment:
The bill Ior service hereunder may be increased or decreased as provided by the Standard
Fuel Adjustment Clause.
Purchase Power Capaeiq and Transmission Charge:
The bill for service hereunder may be increased or decreased as provided by the. Purchase
Power Capacity and Transmission Charge.
Rate Filed: ,lune 19, 2017
Effective: On. Billings on or After July 1, 2017
Filed By: Coleen M. O'Brien, General Manager
'Town of Reading, Massachusetts
Municipal Light Department
MDPU # 271 supersedes
and cancels YIDPU #262
Commercial Schedule C Rate (cont'd)
Measurement of Billing Demand:
The billing demand shall be the highest of the liftcen minute kilowatt demand established
during the billing period, but not less than eighty percent of the maxiillUrn demand
established during the preceding summer season or sixty percent of the maxinitml
demand established during the winter season.
Definitions of Seasons:
The summer season is defined as the months of June thraugh September and the winter
season is defined as the months of October tlu•otigll May.
Farm Discount:
Customers who meet the eligibility requirements set forth by the Massachusetts
Department ol' Food and Agriculture for being engaged in the business of agriculture or
farming, and upon certification to the RMLD by the Masslchusetts Department of Food
and Agriculture, will be eligible for an additional ten percent discount, prior to [lie
RML.D prompt payment discount, on rates and charges applicable oil their monthly
billing statement.
Customer Transformer Ownership:
A customer requiring a minimal transformer capacity of over 2,000 kW will be required
to furnish its own transforming and protective equipment, including slat, vault, primary
and secondary cables, conduits, CtC., Which must comply with the specifications ofthe
Department, The I61lowing diSCOUnts apply when the above is Complied with:
$.12 per kilowatt ofdemand when the service is taken at 2,400/4,160 volts.
$.25 per Kilowatt ofdemand when the service is taken it 13,800 volts.
$.375 per Kilowatt ofdemand when the service is taken at 34,500 volts.
Primary Metering Discount:
The Department may, at its option. meter at the cusulnler's utilization voltage or oil the
high side of the transformer through Which the service is furnished. in the latter case, or
if the customer's utilization voltage requires no transformation, a discount of 1.8% will be
applied to the bill's consumption charges but in no case will SUch diSCOUnt be allowed if
the metering voltage is less than 2,400 voltage.
Rate Filed: .lune 19, 2017
Effective: On Billings on or After July 1, 2017.
Filed By: Coleen Ni. O'Brien, General Manager
Town of Reeding, Massachusetts MDPU 4 271 supersedes
Municipal light Department and cancels MDPU €f 262
Commercial Schedule C Rate (cont.'d)
Meter Reading and Billing:
Bills under this schedule will be rendered monthly. A prompt payment discount of 15%
will be allowed on the Customer Charge, Distribution Demand Charge and Distribution
Energy Charge, only, if the entire bill is paid -in -bill by the discount due date,
General Terms:
Service hereunder is subjCct 10 the General 'Perms and Conditions which are incorporated
herein and are a part of this rate Schedule.
Rate Filed: June 19, 2017
Effective: On Billings on or After July 1, 2017
Filed By: Coleen M. O'Brien, General Manager
Town of Reading, Massachusetts
;Municipal Light Department
MUPU # 272 supersedes
and cancels iMDPU 9 263
Industrial Time -of -Use Schedule I Rate
Designation:
Industrial Time -of -Use I Rate
Available in:
Reading, I.ynnfield Center, North Reading, and Wilmington
applicable to:
Service under this rate is available to industrial or commercial customers who take all
their requirements under this rate. All electricity furnished under this ripe will be
metered using an electronic meter capable of metering On -Peak and 017=Peak energy as
well as kW demand.
Character of service:
A.C. 60 cycles: single phase or three phase.
Customer Charge:
$37.49 per month.
Distribution Demand Charge:
$9.37 per Kilowatt for all demand usage.
Definition of Periods:
The On -Peak period is defined as the h6Urs between 12:00 Noon and 7:00 P:>V1., Monday
through Friday except holidays -as listed below. The Off -Peak period is defined as the
hours between 7:00 PAI. and 12:00 Noon, Monday through Friday and all hours
Saturday, Sunday and granted holidays as listed below.
Term:
A customer erecting to be billed under this rate must remain on this rate for a minimum
of one near. At the end of oneyear oh this rate a customer may elect to remain on this
rate or be billed under the Commercial C Rate.
Energy Conservation Charge:
Tile bill for service hereunder may be increased or decreased as provided by the Energy
Conservation Charge.
Fuel Adjustment:
The bill for service hereunder may be increased or decreased as provided by the Standard
Fuel Adjustment Clause.
Purchase Power Capacity and Transmission Charge:
The bill for service liereunder may he increased or decreased as provided by the Purchase
Power Capacity and 'Transmission Charge.
Rate Filed: June 19, 2017
Effective: On Billings on or After July 1, 2017
Filed By: Coleen M. O'Brien, General Manager
Town of Reading, Massachusetts
Municipal Light Department
i (DPU # 272 supersedes
and cancels MDPU # 263
Industrial Time -of -Use Schedule I Rate (cont'd)
Measurement of Billing Demand:
The Billing demand shall be the highest of the litteen minute On Peak kilowatt demand
established during the billing period, bUt not less than eighty percent of the ma\inlunl
On Peak demand established during the preceding summer season or sixty percent of the
maxinlum On Peak demand established during the winter season.
The summer seftson is defined as the months of JUnC through September and the winter
season is defined as the months of October through A'lay.
Farm Discount:
Customers who meet the eligibility requirements set fbrth by the Massachusetts
Department of Food and Agriculture for being.engaged in the business of agrieulttUre or
farming, and upon certification to the RMLD by the Massachusetts Department of Food
and Agriculture, Nvill be eligible fin• an additional ten percent discount, prior to the.
RNILD prompt payment discount, on rates and charges applicable on their monthly
billing statement.
Customer Transformer Ownership:
A Customer requiring a minimal transformer capacity of over 2000 kW will be required to
furnish its own transforming and.protective equipment, including mat, vault, primary and
secondary cables, conduits. etc., which 111USt Comply with the specifications of the
Department. The li61lowing discounts apply when the above is complied with:
$.12 per Kilowatt of demand when the service is taken at 2,400!4,160 volts.
$.25 per Kilowatt of demand when the service is taken at 13,800 volts.
$.373 per Kilowatt of demand when the service is taken at 3=4,500 volts.
Priman, Metering Discount:
The Department may, at its option, meter at the customer's utili-ration voltage or on the
high side ofthe transformer through which the service is furnished. In the latter case, or
if the customer's utilization voltage requires no transformation, a discount 01'1.8% will be.
applied to the bill's consumption charges but in no case will such.diseount be allowed it'
the metering voltage is less than 2.100 voltage.
Rate Filed: June 19, 2017
i:ffective: On Billings on or After,iuly 1, 2017
.Filed By: Coleen NI. O'Brien, C:eneral Manager
Town of Reading, Massachusetts MDPU # 272 supersedes
Municipal Light Department and cancels MDPU # 263
Industrial Time -of Use Schedule 1 Rate (cont'd)
Meter Reading and Billing:
Bills under this schedule will be rendered monthly. A prompt. payment discount of 15%
will be allowed oil the Customer Charge, Distribution Demand Charge and. Distribution
Energy Charge, only if the entire bill is pai&in-!till by the discount due date.
Granted Holidays
Under the Industrial Time-of=Use Schedule 1 Rate the holidays for O1't=Peak are;
New Year's Day,'President's Day. Memorial Day, Independence Day, Labor Day,
Thanksoiving Day, Columbus Day, Veteran's, Day and Christmas Day,
General Terms and Conditions:
Service hereunder is subject to the General Terns and Conditions which are incorporated
herein and are a part of this rate schedule,
I
Rate Filed: June 19, 2017
Effective: On Billings on or After July 1, 2017
Filed By: Coleen M. O'Brien, General Manager
Town of heading, Massachusetts MDPCI 0 273 supersedes
Municipal Light Department anti cancels MDPU h 263
School Schedule SCH Rate
Designation:
School SCH Rate
Available in:
Reading, Lynnlield Center, North Reading, and Wilmington
Applicable to:
Applicable to public or private schools offering kindergarten, regular elementary, middle,
and high school as approval by the Department, who take all their requirements under
this rate. All electricity furnished under this rate will be metered through one service
urilcss it is convenient for the Department to do otherwise.
Character of service:
AC 60 cycles: single phase or three phase.
Customer Charge:
$6.89 per month.
Distribution Demand Charge:
$720 per Kilowatt for all demand usage.
Distribution Energy Charge:
$.01136 per Kilowatt-hour for all KiIONVatt-hOLII"S LISage.
Budget Billing:
The customers tinder the School Rate may elect the Budget Billing program under which
the customer is required to pay levelired amount to.the Department each billing period
during the calendar year.
Energy Conservation Charge:
The bill for service hCreundCr may be increased or decreased as provided by the Energy
Conservation Charge..
Fuel Adjustment:
The bill for service hereunder may be increased or decreased as provided by the Standard
Fuel Adjusuihent Clause.
Purchase Power Capacity and Transmission Charge:
The bill for service hereunder may be increased or decreased as provided by the Purchase
Power Capacity and Transmission Charge.
Rate Filed: June 19, 2017
Effective: On'Billings on or After July 1, 2017
Filed By: Coleen NJ. O'Brien, Central Manager
Town of Reading, Massachusetts MDI'U # 273 supersedes
Municipal Light Department and cancels MDI'L► 9 261
School Schedule SCH Rate (cont'd)
Measurement of Billing Demand::
The billing demand shall be the highest of the lifteen minute Kilowatt demand
established during the billing period, but not less than eighty percent ofthe maximum
demand established during the preceding summer season or sixty percent of the
maximum demand established during the winter season.
Definitions of Seasons:
The sutnmer season is defined as the months Of Aine through September and the winter
season is defined as the months of October through May.
Customer Transformer Ownership:
A customer requiring a minimal transformer capacity of over 2000 kW will be required to
furnish its own transforming and protective equipment, including mat, vault, primary and
secondary cables, conduits, etc., which must comply with -the: specifications of the
Department. The following discounts apply when the above is complied with:
.$.12 per kilowatt of demand when the service is taken at 2,400%4,160 volts.
S.25 per Kilowatt of demand when the service is taken at 13,800 volts.
5.375 per Kilowatt of demand when the service is taken at 34,500 volts.
Metering:
The Department may, at its option, meter at the custo ner's utilization voltage or on the
high side of the transformers through which the serviceis furnished.
In the latter case, or if the customer's utilization voltage requires no transformation, a
discount of 1..8%o will be applied to the bill but, in no case will such a discount be allowed
if the metering voltage is less than 2,400 volts.
Meter Reading and Billing;:
Bills under this schedule will be rendered monthly. A prompt payment discount ol' 15%
will be allowed on the Customer -Charge, Distribution Demand Charge and Distribution -
Energy Charge, only if the entire, bill is paid -in -full by the disc=ount due date.
General Terms:
Service hereunder is subject to the General "Perms and Conditions which are incorporated
herein and are a part of this rate schedule.
Rate Filed: June 19, 2017
Effective: On Billings on or After July 1, 2017
Filed By: Colcen M. O'Brien, General Manager
Town of Reading,.Massachusetts
Municipal Light Department
Designation:
Residential RW Rate
MDPU # 27.1 supersedes
and cancels MDPU # 260
Residential Schedule RW'
Controlled Nater Heater Rate
Available in:
Reading, Lynnfield Center. North Reading, and Wilmington
Applicable to:
Individual residential customers tax• all domestic Lues where service is taken through one
meter. Incidental commercial use, not exceeding 20% of the total energy Used oil the same
premises is permitted.
Character of service:
A.C. 60 cycles: single phase.
Terms of Use:
When a customer regularly uses an electric water heater of a type approved by the
Department, service to the water heater will be controlled by a Department owned timing
device. Customer also needs a customer owned internet connection. Internal wiring will
be the responsibility of the customer. Water heater with two elements shall be
interlocked to prevent simultaneous operation,
Customer Charge:
$4.82. per month.
Distribution Energy Charge:
S.0=4832 per Kilowatt-hour for all Kilowatt-hours usage
Budget Billing:
The customers under this rate will have available to them a budget billing program Under
which the customer is required to pay a Ievelized amount to the Department each billing
period during the calendar year.. 'file specifics of this program are outlined in the
Department's General 'terms and Conditions.
Low Income Discount
"I'he Customer Charge under this rate will be waived upon verification ora low-income
customer's receipt of any means -tested public benefit, or verification of eligibility for the
low -Income home energy assistance program, of its SUCCeSSor program, for which
eligibility does not exceed 200 percent of the federal poverty level based on a
household's gross income. In a program year ill which maximLim eligibility fir LIFIF-AP
exceeds 200 percent of the flederal poverty level, a household that is income eligible
under LII IEAP shall be eligible fur the luw-inconle electric- diSeOUrll. It is the
responsibility of the- customer to annually certify, by forms provided by the utility, the
continued compliance with the foregoing qualifications.
Rate Filed: ,June 19, 2017
i?ffective: On Billings on or After ,July 1, 2017
Filed By: Coleen M. O'Brien, General Manager
Town of Reading, Massachusetts
Municipal Light Department
PY
NIDPU # 274 supersedes
and cancels MDPU # 260
Residential Schedule R«<
Controlled Water Heater Rate (cont'd)
Farm Discount:.
CLIStomers who Ineel the eligibility requirements set forth by the Massachusetts
Department of rood and Agriculture for being engaged in the bLISlness ofagrlCllltlll'e of
]arming; and. upon certification to the RNILD -by the Massachusetts Department of Food
and Agriculture, will be eligible for an additional 10% discount, prior to the RMLD
prompt payment discount, on rates and charges applicable on their monthly billing
statement.
Energy Conservation Charge:
The bill Por service hereunder may be increased.or decreased as provided by the Energy
Conservation Charge.
Fuel Adjustment:
The bill for service hereunder may be increased or decreased as provided by the Standard
Fuel Adjustment Clause.
Purchase Power Capacity and Transmission Charge:
The bill 1'6r service hereunder may be increased or decreased as provided by the Purchase
Power Capacity and Transmission Charge
Meter Reading and Billing:
Bills under this schedule will be tendered monthly. A prompt payment diSCOLIIIt of 15%
will be allowed on the Customer Charge and Distribution, Energy Charge, only ifthe
entire bill is paid -h lull by the discount due date.
General Terms and Conditions:
Service hereunder is subject to the General 'Perms and Conditions which are incorporated
herein and area part of this rate schedule.
Rate Filed: June 19, 2017
Effective: On Billings on or After July 1, 2017
Filed By: Coleen. M. O'Brien, General Manager
Town of Reading, Massachusetts N1DPU i# 275
Municipal Light Department
Backup and Standby Rate
Designation:
Backup and Standby Rate
Available in:
Reading, L_ynntield Center, North Reading, and Wilmington
Applicable to:
This rate shall be applied to all partial requirements general service Customers tithe Customer).
A partial requirements Customer is defined as one who normally generates all, or a portion of
the Customer's electrical power and energy requiremerils. All electricity supplied shall be for the
exclusive use of the Customer and shall not be resold. Service taken tinder this rate shall be
electrically separated From the Customer's generating Facilities or provided with sufficient
protective devices to prohibit such Facilities from causing disturbances on the RNiLD's system
consistent with the. RMLD's Terns and Conditions. The RMLD reserves the right to refuse
service to facilities where the RMLD reasonably detennines that the protection provided is
inadequate.
All electricity supplied to the Customer by the RNILD shall be measured through one meter,
except that where the RNILD deems it impractical to deliver electricity through one service, or
where the RMLD has installed more than one meter, then the. measurement of electricity may
be by two or more meters: When the Customer's generating facilities are capable of operating
in parallel with the RMLD's supply, the Customer shall furnish, at its expense, necessary
facilities. for metering equipment including a dedicated voice grade telephone circuit for remote
reading whereby the RMLD can meter the output of the Customer's generating facilities.
Character of service:
Finn Backup Service
Finn Backup Service is intended to provide the. Customer with a finn supply of electric power
and energy when the Customer's generating facilities are not in operation or are operating at Fess
than full rated capability or when the Customer's load is greater than the capability of its
generating facilities. To obtain service under this schedule, the Customer must specify in writing
the maximum Finn back-up electric power demands (Finn Backup Contract Demand) that it
plans to impose on the RMLD under this schedule. The amount of Finn Backup Contract
Demand may be changed only by written notification to the RMLD at least six months prior to
the effective date of such change. The RMLD reserves the right to refuse any increase in the
Firm Backup Contract Demand if, in the sole judgment of the RMLD, such an increase would
have an adverse impact on the reliability,or cost of the provision of firm service to any of: the
RINILD's Finn service customers.
Standbv Service
Rate Filed: June 19, 2017
Effective: On Billings on or after July 1, 2017
Filed By: Coleen IM. O'Brien, General Manager
Town of Reading, Massachusetts
N,Iunicipal Light Department
MDPU # 275
Standby Service is intended to reserve capacity on the RMLD's transmission and
distribution system for the delivery of Firm Backup Service. Standby ServicewiII be taken
and paid for regardless of whether Finn Backup Service is taken hi any month.
Definitions
Firm Backup Contract Demand: the maximum firm backup electric power demand
which the Customer shall impose on the RMLD as specified by the Customer.
Firm Backup Demand: the maximum. metered billing demand occurring in the
billing period or the Finn Backup Contract Demand, whichever is less.
Metered Energy: the Customer's actual electrical load without the application of the
Customer's generation.
Billing Energy: the electrical load imposed on the RMLD's system.
Backup Energy: tile sum of the kWh of Billing Energy for the period.
Metered Demand: the greatest actual ,etectrieal bird during any 15 minute period
without the application of the Customer's generation.
Billing Demand: the Greatest 15 minute electrical load imposed .on. the RMLD's
system during thebilling period.
Applicable General Service Rate: the rate under which the customer would be
eligible to receive firm service from the RNILD if the. Customer did not
generate any of its, own electric power and energy requirements.
All demands refer to fifteen (15) minute kW demands.
Monthly Rates
Customer Charge: The customer charge in Applicable General Service
Rate.
Demand Rates:
Standby Demand: The Distribution Demand Rate in the Applicable
General Service Rate multiplied by the Finn
Backup Contract Demand.
Firm Backup Demand: The Distribution Demand rate in the Applicable
General Service Rate=iltiplied by the Finn
Backup Demand.
Energy Rates:
Backup Energy The energy rate, including the Energy Conservation
Charge, Fuel Adjustment and Purchased Power
Adjustment, in the Applicable General Service Rate
per billing kWh.
Rate. Filed: June 19, 2017
Effective: On Billings on or after July 1, 2017
Filed By: Coleen NI. O'Brien, General tllanagei
Town of Reading, Massachusetts
Municipal Light Department
NiDPU # 275
Stranded Cost Charge The Distribution Energy Charge in the Applicable
General Service Rate multiplied by the Metered
Energy
The monthly charge shall be the sum of the Customer Charge, the Standby Demand Charge,
the Film Backup Demand Charge, the Backup Energy Charge and the Stranded Cost
Charge,
Term:
Unless otherwise agreed in writing, service under this rate shall be for a period of not less
than three years and thereafter may be discontinued only upon the RMLD's receipt of a 90 -
day written notice. Service is also .subject to the provisions of the Rules and Regulations of
the RMLD.
Measurement of Billing Demand:
The Billing demand shall be the highest ofthe fifteen minute kilowatt demand established
during the billing period, but not less than eighty percent of the maximum demand
established during the preceding summer season or sixty percent of the maximum demand
established during the winter season.
Farm Discount:
Customers who meet the eligibility requirements set forth by the Massachusetts
Department of Food and Agriculture for being engaged in the business of agriculture or
farming, and upon certification to the RMLD by the Massachusetts Department of Food
and Agriculture, will be eligible for an additional ten percent discount, prior to theRMLD
prompt payment discount, on rates and charges applicable on their monthly billing
statement.
Customer Transformer Ownership:
A customer requiring a minimal transformer capacity of'over 2000 kW will be required to
fi►rlish its own transforming and protective equipment, including mat, vault, primary and
secondary cables, conduits, etc., which must comply with the specifications of the
Department. The following discounts apply when the above is complied with:
S. 12 per Kilowatt of demand when the service is taken at 2,400/4,160 volts.
S.25 per Kilowatt of demand when the service is taken at 13,800 volts.
S.375 per Kilowatt of demand when the service is taken at 34,500 volts.
Nletering:
The Department may, at its option, meter at the customer's utilization voltage or on the
high side of the transformer through which the service is furnished. In the latter case, or if
the customer's utilization voltage requires no transformation, a discount of 1.8% will be
applied to the bill but in no case will such discount be allowed if the metering voltage is
less than 2,400 voltage.
Nleter Reading and Billing:
Rate Filed: June 19, 2017
Effective: On Billings on or after July 1, 2017
Filed By: Coleen Ni. O'Brien, General Manager
Town of Reading,. Nlassachusetts
Municipal Light Department
NIDPU # 275
Bills under this schedule will be rendered monthly. A prompt payment discount of 15%
will be allowed on the Customer Charge, Standby Demand Charge, Firm Backup Demand
Charge, and Distribution Energy Charge, only if the entire bill is paid -in -full by the
discount due date.
General Terms and Conditions:
Service hereunder is subject to the General Terms and Conditions which areincorporated
herein and are a part of this rate schedule.
Rate Filed: June 19, 2017
Effective: On Billings on. or after July 1,, 2017
Filed By: Colcen NI. O'Brien, General Manager
Town of Reading, Massachusetts
Municipal Light Department
i1•IDPU # 276 supersedes
and cancels. NIDPU # 236
Purchase Power Capacity and Transmission Charge
Applicability:
The Purchase Power Capacity aild Transmission Charge, or the annual average base
power supply base costs, shall be applied to all customers receiving service under any rate
schedule of the Department.
Power Cost Amount:
The Purchase Power Capacity and Transmission Charge amount shall be the total amount
of all power and transmission charges incurred by the Department, exclusive of fuel, for
electric service to all customers. Such cost shall be computed periodically on actual or
estimated power billings and divided by the total kilowatt-hour sales to all customers for
that month. The resultant cost shall be rounded to the nearest 5.00001/kilowatt-hour.
For customers receiving service under the Department's Industrial Time -of -Use I Rate
(N1DPU 4272) the power cost amount will be expressed as a demand charge in SMAI of
demand. The demand charge will be calculated to recover the same revenue as the per -
kilowatt -hour charge applied to all other customers.
Calculation of the Purchase Power Capacity and Transmission Charge:
The Purchase Power Capacity and Transmission Charge shall equal the power cost
amount. The resultant charge shall be applied to all bills in tile following month.
Other Charges and Credits:
By order of the Reading Nlunicipal Light Board, die Purchase Power Capacity and
Transmission Charge may reflect additional one-time or irregular credits resulting from
power refunds, out of period adjustments or reduced power reserve needs.
Rate Filed: June 19, 2017
Effective: On Billings on or After July 1, 2017
Filed By: Coleen M. O'Brien, General Manager
Town of Reading, Massachusetts MDPU # 277
Municipal Light Department
Electric Vehicle Supply Equipment Schedule EVSE Rate
Designation:
Electric Vehicle Charger (EVSE) Rate
Available in:
Reading, Lynnfield Center, North Reading, and Wilmington
Applicable to:
This rate is available to Customers who utilize Electric Vehicle Supply Equipment;
installed and owned by RMLD.
Character of service:
AC 60 cycles: single phase or three phase.
Distribution Energy Charge:
$.1111 per Kilowatt-hour for all Kilowatt-hours usage
Fuel Adjustment:
The rate for service hereunder may be increased or decreased as provided by the Standard
Fuel Adjustment Clause.
Purchase Power Capacity and Transmission Charge:
The rate for service hereunder may be increased or decreased as provided by the Purchase
Power Capacity and Transmission Charge.
Meter Reading and Billing:
Service under this schedule will be rendered immediately. Payment due at point of sale.
General Terms and Conditions:
Service hereunder is subject to the General Terms and Conditions which are incorporated
herein and are a part of this rate schedule.
Rate Filed: June 19, 2017
Effective: On Billings on or After July 1, 2017
Filed By: Coleen M. O'Brien, General Manager
FINANCIAL REPORT
MARCH & APRIL 2017
ATTACHMENT 4
FINANCIAL REPORT
IAPRIL 302017
s
0.95
0.9
F -
z
w
0.85
U
w
FF5
z
0.8
w
U
W
a
0.75
0.7
JULY AUG
= FY15 = FY16 = FY17
SEP OCT NOV DEC JAN FEB MAR APR
MONTHS OF YEAR
$25,000,000.00
$20,000,000.00
$1S,000,000.00
$10,000,000.00
$5,000,000.00
$0.00
Base Revenue & Operating Expenses Comparison
July -April FY16 and FY17
10% increase
Base Revenue Operating Expenses
■July -April FY16 (10 months) ■July -April FY17 (10 months)
PPCT
FUEL
PPCT and Fuel Revenue and Expenses
July 16 -April 17 FY17 (10 months)
® Revenue ® Expense
Year to Date Operating and Maintenai
Comparing FY16 FY17
and FY17 Budget
July 2016 — April 2017 (10 moi
$18,000,000.00
$16,000,000.00
$14,000,000.00
$12,000,000.00
$10,000,000.00
$8,000,000.00
$6,000,000.00
$4,000,000.00
$2,000,000.00
April
ch
� Year to Date
Yearto Date
j
Year to Date
July
j FY16_ActuaI
$1,315,415.23
FY17 Actual
Budget
$1,399,966.01
$1,783,203.00
IN Aug
$2,918,703.69
$3,134,666.17
I $3,566,406.00
® Sept
��.--
$4,461,345.01
$4,904,753.21
I $5,349,609.00
j ■ Oct
$6,272,430.27
! $6,493,213.21
I $7,132,812.00
■ Nov
$7,627,630.82
$8,309,938.88 $8,916,015.001
i Dec
$9,441,533.29
$10,144,029.301_$10,699,218.00
.3 -----_
■Jan
■ Feb
$10,901,861.33
1 $12,563,605.41
$12,232,069.66 $12,482,421.001
; $13,874,351.50 $14,265,624.00 1
® March
1 $14,297,906.28
$15,643,132.30 $16,048,827.00
ISApril
$15,915,181.84
$17,537,887.481 $17,832,030.00'
April
ch
ENGINEERING & OPERATIONS REPORT
MARCH & APRIL 2017
ATTACHMENT 5
READING MUNICIPAL LIGHT DEPARTMENT
FOR PERIOD ENDING MARCH 2017
STATION UPGRADES:
ALL
169,667
ACTUAL
YTD ANNUAL
REMAINING
PROJ DESCRIPTION TOWN
COST
ADDITIONS BUDGET
BALANCE
CONSTRUCTION:
48,904
(64,305)
109
106 Underground Facilities Upgrades (URD's, Manholes, etc) ALL
31,801
296,716 149,965
(146,751)
107 13.8kV Upgrade (Step-down areas, etc.) ALL
1.646
6,555 105,748
99,193
SUB -TOTAL
33,447 303,271 256.713 (47,558)
NEW CUSTOMER SERVICES: 141-146
New Service Installations (Commercial / Industrial) ALL 6,325 86,451 139,570 53,119
SUB -TOTAL 6,325 86,451 139,570 53,119
STATION UPGRADES:
ALL
169,667
1,341,271
1,012,962
(328,309)
108
Station 4 (GAW) Relay Replacement Project
R
113,209
48,904
(64,305)
109
Station 4 35kV Potential Transformer/Replacement
R
57
-
(57)
110
4W9 Getaway Replacement -Station 4
R
2,622,933
104,513
234,747
130,234
111
Substation Equipment Upgrade (all)
ALL
192,232
-
74,590
74,590
113
Station 4 (GAW) Battery Bank Upgrade
R
-
24,000
17,037
(6,963)
120
Station 4 - Relay/SCADA Integration for Bus A&B
R
26,964
51,225
70,308
19,083
130
Station 3 - Remote Terminal Unit (RTU) Replacement
NR
24,850
24,850
39,330
14,480
133
Station 3 - Relay Upgrades and SCADA Integration
NR
4,416
255,052
252,225
(2,827)
139
Station 5 - LTC Control Replacement
W
-
6,324
41,543
35,219
140
Substation Grounding Equipment Upgrade
ALL
-
125
20,671
20,671
70,440
SUB -TOTAL
360,000
56,230
579,231
799,355
220,124
NEW CUSTOMER SERVICES: 141-146
New Service Installations (Commercial / Industrial) ALL 6,325 86,451 139,570 53,119
SUB -TOTAL 6,325 86,451 139,570 53,119
TOTAL CAPITAL BUDGET $ 570,124.33 $ 4,564,999 $ 9,406,216 $ 4,841,217
ROUTINE CONSTRUCTION:
ALL
169,667
1,341,271
1,012,962
(328,309)
SPECIAL PROJECTS / CAPITAL PURCHASES:
100
Distributed Gas Generation (Pilot FY16-17)
ALL
5,396
97,476
2,720,409
2,622,933
102
Padmounl Switchgear Upgrade at Industrial Parks
W
-
2,286
194,518
192,232
103
Grid Modernization and Opitmization
ALL
9,885
232,024
284,000
51,976
105
New Wilmington Sub -Station
W
-
-
250,000
250,000
112
AMI Mesh Network Expansion
ALL
125,394
220,021
94,627
115
Fault Indicators
ALL
-
1,340
25,000
23,660
116
Transformers and Capacitors
ALL
151,110
160,212
668,000
507,788
117
Meter Purchases
ALL
2,145
30,381
80,000
49,619
125
GIS
ALL
70,440
250,217
360,000
109,783
126
Communication Equipment (Fiber Optic)
ALL
-
7,064
69,173
62,109
131
LED Street Light Implementation
ALL
40,644
525,770
804,070
278,300
134
Substation Test Equipment
ALL
-
14,270
30,000'
15,730
135
Analog Devices Cap Bank Upgrade
W
548
54,188
53,640
136
Voltage Data Recorders
ALL
-
-
25,000
25,000
SUB -TOTAL
279,619
1,446,981
5,784,379
4,337,398
OTHER CAPITAL PROJECTS:
96
Control Center Modifications
ALL
-
-
100,000
100,000
97
HVAC Roof Units - Garage
R
44,484
-
(44,484)
98
Carpet Upgrade
R
10,950
71,653
60,703
99
Electric Vehicle Supply Equipment
ALL
(1,303)
-
10.000
10,000
104
RMLD Lighting (LED) Upgrade
-
25,000
25,000
118
Rolling Stock Replacement
ALL
53,083
310,000
256,917
119
Security Upgrades All Sites
ALL
-
34,684
5,000
(29,684)
121
HVAC System Upgrade - 230 Ash Street
R
8,000
527,550
500,000
(27,550)
127
Hardware Upgrades
ALL
9,389
75,668
112,065
36,397
128
Software and Licensing
ALL
8,750
61,376
230,519
169,144
129
Master Facilities Site Pian
R
-
50,000
50,000
SUB -TOTAL
24,837
807,794
1,414,237
606,443
TOTAL CAPITAL BUDGET $ 570,124.33 $ 4,564,999 $ 9,406,216 $ 4,841,217
READING MUNICIPAL LIGHT DEPARTMENT
CAPITAL VARIANCE REPORT
FOR PERIOD ENDING APRIL 2017
NEW CUSTOMER SERVICES: 141-146
New Service Installations (Commercial / Industrial) ALL 7,513 93,964 139,570 45,606
SUBTOTAL 7,513 93,964 139,570 45,606
ROUTINE CONSTRUCTION:
ALL
ACTUAL
YTD
ANNUAL
REMAINING
PROJ
DESCRIPTION
TOWN
COST •
ADDITIONS
BUDGET
BALANCE
CONSTRUCTION:
100
Distributed Gas Generation (Pilot FYI 6-17)
ALL
690,997
106
Underground Facilities Upgrades (URD's, Manholes, etc)
ALL
1,905
298,621
149,965
(148,656)
107
13.8kV Upgrade'(Step-down areas, etc.)
ALL
3,258
9,813
105,748
95,935
258,865
SUB -TOTAL
25,135
5,163
308,434
255,713
(52,721)
-
STATION UPGRADES:
250,000
112
AMI Mesh Network Expansion
ALL
108
Station 4 (GAW) Relay Replacement Project
R
-
113,209
48,904
(64,305)
109
Station 4 35kV Potential Transformer Replacement
R
116
57
-
(57)
110
4W9 Getaway Replacement -Station 4
R
117
104,513
234,747
130,234
111
Substation Equipment Upgrade (all)
ALL
125
-
74,590
74,590
113
Station 4 (GAW) Battery Bank Upgrade
R
126
24,000
17,037
(6,963)
120
Station 4 - Relay/SCADA Integration for Bus A&B
R
131
51,225
70,308
19,083
130
Station 3 - Remote Terminal Unit (RTU) Replacement
NR
134
24,850
39,330
14,480
133
Station 3 - Relay Upgrades and SCADA Integration
NR
879
255,931
252,225
(3,706)
139
Station 5 - LTC Control Replacement '
W
-
6,324
41,543
35,219
140
Substation Grounding Equipment Upgrade
ALL
-
-
20,671
20,671
2,269,719
SUB -TOTAL
3,514,660
879
580,109
799,355
219,246
NEW CUSTOMER SERVICES: 141-146
New Service Installations (Commercial / Industrial) ALL 7,513 93,964 139,570 45,606
SUBTOTAL 7,513 93,964 139,570 45,606
TOTAL CAPITAL BUDGET $ 1,203,958 S 5,768,957 $ 9,406,216 S 3,637,259
ROUTINE CONSTRUCTION:
ALL
265,341
1,606,613
1,012,962
(593,651)
SPECIAL PROJECTS/ CAPITAL PURCHASES: '
100
Distributed Gas Generation (Pilot FYI 6-17)
ALL
690,997
788,473
2,720,409
1,931,936
102
Padmount Switchgear Upgrade at Industrial Parks
W
-
2,286
194,518
192,232
103
Grid Modernization and Opilmization
ALL
26,841
258,865
284,000•
25,135
105
Now Wilmington Sub -Station
W
-
250,000
250,000
112
AMI Mesh Network Expansion
ALL
125,394
220,021
94,827
115
Fault Indicators
ALL
-
1,340
25,000
23,660
116
Transformers and Capacitors
ALL
19,794
180,006
668,000
487,994
117
Meter Purchases
ALL
2,955
33,336
80,000
46,664
125
GIS
ALL
41,366
291,583
360,000
68,417
126
Communication Equipment (Fiber Optic)
ALL
410
7,474
69,173
61,699
131
LED Street Light Implementation
ALL
28,518
554,289
804,070
249,781
134
Substation Test Equipment
ALL
11,855
26,125
30,000
3,875
135
Analog Devices Cap Bank Upgrade
W
-
548
54,188
53.640
136
Voltage Data Recorders
ALL
-
25,000
25,000
SUBTOTAL
822,738
2,269,719
5,784,379
3,514,660
OTHER CAPITAL PROJECTS:
96
Control Center Modifications
ALL
100,000
100,000
97
HVAC Roof Units - Garage
R
44,484
(44,484)
98
Carpet Upgrade
R
10,950
71,653
60,703
`99
Electric Vehicle Supply Equipment
ALL
-
10,000
10,000
104
RMLD Lighting (LED) Upgrade
25,000
25,000
118
Rolling Stock Replacement
ALL
53,083
310,000
256,917
119
Security Upgrades All Sites
ALL
34,684
5,000
(29,684)
121
HVAC System Upgrade - 230 Ash Street
R
77,186
604,736
500,000
(104,736)
127
Hardware Upgrades
ALL
9,298
84,966
112,065
27,099
128
Software and Licensing
ALL
15,840
77,216
230,519
153,304
129
Master Facilities Site Plan
R
50,000
50,000
SUBTOTAL
102,325
910,119
1,414,237
504,118
TOTAL CAPITAL BUDGET $ 1,203,958 S 5,768,957 $ 9,406,216 S 3,637,259
Igineering & Operations
Aft
RMLD Board of Commissioners Meeting
June 15, 2017
March and April 2017 Reporting Period
Hamid Jaffari, Director of Engineering & Operations
11111 '11
MO rFro i � �
Distributed Gas Generator Pilot
20%
$5,396
F' - -_ - _ - i
$690,997.i $788,473;
Underground Facilities Upgrades (URDs, Manholes, etc.)
- -- -
• Crestwood Road, North Reading
On-going
$31,801.
$1,905 $298,621;
Robin Road, North- Reading
13.8kV Upgrade (Step-down Areas, etc.)
• Main Street, Lynnfield
• Main Street Reading
On-going '
$1,646
$3,258' $9,8131
Summit Tower,_ Reading_
Station 4: Relay/SCADA Integration for Bus A&B
100%
$26,964
$51,225,
Station 3: Remote Terminal Unit (RTU) Replacement
40%
$24,850'
$24,850!i
Station 3: Relay Upgrades and SCADA Integration
70%
$4,416
$879, 255,931;
Service Installations - Residential and Commercial:
, e
This item includes new or upgraded overhead and
On-going
$6,325'
$7,513; $93,964;'
underground services.
Grid Modernization and Optimization - — --y
On-going
$9,885
a
$26,841 ; $258,865!;
GIS
75%
$70,440
$41,366 $291,583:.
LED Street.Light Conversion.
65%
$40,644.$28,5181
$554,289
Routine Construction
Pole Setting/Transfers
Overhead/Underground
Projects Assigned as Required
• Station - 1 15kV Reclosing Automation, R
• Voltage Regulators, LC
• Pumping Stations (West Street and Batchelder Road), R
• 234 Ballardvale Street - Keolis, W
_ •__ AT&T Appl W_1572 (Industrial/West), W_
Pole Damage/Knockdowns - Some Reimbursable
• Work was done to repair or replace six (6) poles
MAR
APR
$52,374; $29,720
$48,746 $15,348
$25,769 $174,
$5,932
$4,13
;Station Group
$12,078, $6,247
Hazmat/Oil Spills
$1,240 -
• Concord Street, NR
Porcelain Cutout Replacement Program
- -
Lighting (Street Light Connections)
$4,341 $2,41,
Storm Trouble
$13,957 -
Underground Subdivisions (new construction)
$1 102
• Dogwood Lane, North Reading
Animal Guard Installation
$108
Miscellaneous Capital Costs
$4,020 $32,99C
TOTAL:
YTD
$332,50
$339,546
$354,111
$94,40
7il 67�
$7,037
$26, 62 3
$45,812
$46,931
$1,162
1 $17 614 9
Routine Maintenance
Transformer Replacement (through April 2017)
Pad mount 26.17% Overhead 17.09%
Pole Inspection (as of 5/26/17)
231 poles have been replaced 130 of 231 transfers have been completed
Quarterly Inspection of Feeders (through May 25, 2017)
Inspected Circuits (Jan -Mar): 3W5, 3W6, 3W7, 3W8, 3W 13, 3W 14, 3W 15, 3W 18, 4W4, 4W5, 4W6, 4W7,
4W9, 4W23, 4W24, 5W4, 5W5, 5W8, 5W9, 4P9, 4P2
Inspected Circuits (Apr -Jun): 4W 10, 4W 12, 4W 13
w Manhole Inspection (through April 2017)
961 of 1,237 manholes have been inspected.
w Porcelain cutout Replacements (through April 2017)
91 % complete 253 remaining to be replaced
w Tree Trimming
March: 147 spans trimmed April: 144 spans trimmed YTD:
w Substation Maintenance
Infrared Scanning - March and April complete - no hot spots found
1,122 spans trimmed
Double Poles
nership: 16,000 (approximately)
50% RMLD
50% Verizon
todial:
Reading - split (see map)
North Reading - RMLD
Lynnfield - Verizon
Wilmington - Verizon
Town of Reading
Pole Jurisdiction
�S
P it ✓ ' It��
NJ U NS
"Next to Go" as of June 5, 2017
WILMINGTON
Countor Ticket
- _ "--'-- -- - - --"- -- - ---- ---- - ---- NTG Member and JobType I_i Number
READING NORTH READING �n)avlCrmR 1,
Count
L NNFIELD Count of -' Ticket of NTG Member and JobType Irl Ticket of J TRANSFER r
NTG Member and JobType Number ,)NGMA 1, SNP3PMA 7.
Ticket rLTFMA 1 13 National Grid Non -participating 3 rd Party
NTG MemberandJobType Number 0- ightowerFiberNetworks TRANSFER 1 A��ef- ��use
t�
LFLDFD 3'
TRANSFER 7; TRANSFER 1
O- Lynnfield Fire Department
BNP3PMA 1 SNPFAMA 4
TRANSFER 3=NP3PMA 9 Non -participating Fire
NOn-participating 3rd Party _' Alarms - Massadhusetls
Nan -participating 3rd Party Attacher r+ Attacher - Massachusetts TRANSFER 4
O- Massachusetts
FIRMLD 3 TRANSFER 9 TRANSFER 1 32
i�
+=iReadingMunicipal htDepariment =+ReadingMunicipal light Department
TRANSFER 3 ORDNGFD $ 1NRDGFD 44 TRANSFER zaPULPOLE 4
1Reading Fire Department 3 North Ruing Rre Department
TRANSFER g TRANSFER 44 �vzBMA a
= VZNESA 1D 'Verizon Business
7 Verizon TRANSFER 1
TRANS R 5
JRMLD yZ JRMLD 120
S Reading Municipal Li ht De Department -� VZNEDR 79
PULL LE 5 H Reading Municipal Light Depariment g-1Verizon
Jf nk) TRANSFER 34 TRANSFER 13 TRANSFER ss
Grand Total 16 PULL POLE 58 PULL POLE 107 Puts PotE 13
WLMFIB 3
'JVZNESA 79
VZNEDR 24 "1Tow n or Wilmington
,
9 Verizon '_]Verizon TRANSFER 3
TRANSFER 75 TRANSFER 16-,NrMGNFD 84
PULL POLE 4 PULL POLE 8 W huington Fire Department
'J(blank) 6(blank) TRANSFER 94
Grand Total 189 Grand Total 190 Grand Total 211
RMLD Reliability Indices
SAIFI = Total Niiniberof Custonuei-Iiiierniptions
Total Numberof Customers Served
Note: Regional and -national averages have been updated for 2016.
SAIDI 2012-2017
Minutes
Minutes
60.00
120.00
56.77
50.00 T--------
-
111.83
2012
40.00
- 2013
30.00
94.96
2014 IEEE day threshold
27.65
2015 IEEE day threshold
20.00
2016 IEEE day threshold
10.00d!il
-- - - 2017 YTD IEEE day threshold
60.00
—2016 Region Average (no ME)
0.00
64.22,
X2015
2012-2013-2014-2015-2016- —2016 National Average (no ME)
2017
Average SAIDI
{
Total Durationof Customerinterruptions
? S
DI (Minutes) =
0.00
Total Numberof CustomersSetved
dr
2012-2013-2014-2015-2016-2017
Note: The major event (ME) threshold allows a utility to remove outages that
exceed the IEEE 2.5 beta threshold for events. These events could be severe
—2016 National Average
weather, which can lead to unusually long outages in comparison to your
Average CAIDI
distribution system's typical outage.
SAIFI = Total Niiniberof Custonuei-Iiiierniptions
Total Numberof Customers Served
Note: Regional and -national averages have been updated for 2016.
0.90
0.80
0.70
0.60
0.50
0.40
0.30
0.20
0.10
0.00
2012-2013-2014-2015-2016-2017
Average SAIFI
CAIDI (Minutes) = Total Duration of Customer Interruptions
Total Number of Customers Interruptions
SAIR-2012-2017
® 2012
2013
2014
2015
X2016
2017 YTD
—2016 Region Average
— 2016 National Average
CAI DI 2012-2017
Minutes
120.00
111.83
100.00
® 2012
94.96
X2013
80.00
X
2014
60.00
64.22,
X2015
40.00
0
2016
20.00
2017 YTD
0.00
—2016 Region Average
2012-2013-2014-2015-2016-2017
—2016 National Average
Average CAIDI
0.90
0.80
0.70
0.60
0.50
0.40
0.30
0.20
0.10
0.00
2012-2013-2014-2015-2016-2017
Average SAIFI
CAIDI (Minutes) = Total Duration of Customer Interruptions
Total Number of Customers Interruptions
SAIR-2012-2017
® 2012
2013
2014
2015
X2016
2017 YTD
—2016 Region Average
— 2016 National Average
lOutages Causes YTD (from eReliability website)
Weather
i Utility Human
j 0 Error
0% Unknown 0
O/ 0%
Vehicle
I
Accident^ Natural
1 \
0
0
° ®M � 0%
Tree
28
54%
Outages Causes
2017 YTD
April
s
■ Equipment
o Tree
■ Wildlife
■ Vehicle Accident
■ Weather
Unknown
■ Utility Human Error
■ Natural
Vehicl
Unknown
6 Utility Human Error
3% � 2
1% Natural
Annual Average 2012-2017;
i
i
■ Equipment
u Tree
■ Wildlife
■ Vehicle Accident
® Weather
Unknown
■ Utility Human Error
■ Natural
;
i
f
r
A90h
BOARD MATERIAL AVAILABLE
BUT NOT DISCUSSED
TOWN OF READING MUNICIPAL LIGHT DEPARTMENT
RATE COMPARISONS READING 8 SURROUNDING TOWNS
May -17
PEABODY MUNICIPAL LIGHT PLANT
TOTAL BILL $88.38 $172.43 $117.07 $952.31 $151.07 $4,709.23 $638,286.46
PER KWH CHARGE $0.11784 $0.11495 $0.11707 $0.13045 $0.13988 $0.13455 $0.09278
% DIFFERENCE -18.23% -6.63% -10.73% -2.63% -22.48% 3.74% -11.79%
MIDDLETON MUNICIPAL LIGHT DEPT.
TOTAL BILL $98.74 $201.66 $132.75 $959.51 $168.44 $4,762.93 $807,171.40
PER KWH CHARGE $0.13165 $0.13444 $0.13275 $0.13144 $0.15596 $0.13608 $0.11733
%DIFFERENCE -8.64% 9.20% 1.23% -1.89% -13.57% 4.92% 11.56%
WAKEFIELD MUNICIPAL LIGHT DEPT.
TOTAL BILL $115.49 $213.42 $144.38 $1,093.29 $175.48 $5,123.08 $852,765.30
PER KWH CHARGE $0.15398 $0.14228 $0.14438 $0.14977 $0.16249 $0.14637 $0.12396
% DIFFERENCE 6.85% 15.56% 10.10% 11.79% -9.96% 12.86% 17.86%
INDUSTRIAL - TOU
RESIDENTIAL
RESIDENTIAL-TOU
RES. HOT WATER
COMMERCIAL
SMALL COMMERCIAL
SCHOOL RATE
109,600 kWh's
760 kWh's
1600 kWh's
1000 kWh's
7,300 kWh's
1,080 kWh's
36000 kWh's
260.000 kW Demand
76126 Split
26.000 kW Demand
10.000 kW Demand
130.6 kW Demand
80120 Split
READING MUNICIPAL LIGHT DEPT.
TOTAL BILL
$108.08
$184.68
$131.14
$978.03
$194.89
$4,539.50
$723,561.98
PER KWH CHARGE
$0.14410
$0.12312
$0.13114
$0.13398
$0.18045
$0.12970
$0.10518
NATIONAL GRID
TOTAL BILL
$151.90
$358.79
$188.23
$1,363.20
$210.20
$5,412.22
$1,603,701.44
PER KWH CHARGE
$0.20253
$0.23919
$0.18823
$0.18674
$0.19463
$0.15463
$0.23311
%DIFFERENCE
40.55%
94.28%
43.53%
39.38%
7.86%
19.23%
121.64%
EVERSOURCE(NSTAR)
TOTAL BILL
$143.50
$253.51
$189.19
$1,233.41
$203.03
$6,692.17
$936,202.98
PER KWH CHARGE
$0.19133
$0.16901
$0.18919
$0.16896
$0.18799
$0.19120
$0.13608
%DIFFERENCE
32.77%
37.27%
44.27%
26.11%
4.18%
47.42%
29.39%
PEABODY MUNICIPAL LIGHT PLANT
TOTAL BILL $88.38 $172.43 $117.07 $952.31 $151.07 $4,709.23 $638,286.46
PER KWH CHARGE $0.11784 $0.11495 $0.11707 $0.13045 $0.13988 $0.13455 $0.09278
% DIFFERENCE -18.23% -6.63% -10.73% -2.63% -22.48% 3.74% -11.79%
MIDDLETON MUNICIPAL LIGHT DEPT.
TOTAL BILL $98.74 $201.66 $132.75 $959.51 $168.44 $4,762.93 $807,171.40
PER KWH CHARGE $0.13165 $0.13444 $0.13275 $0.13144 $0.15596 $0.13608 $0.11733
%DIFFERENCE -8.64% 9.20% 1.23% -1.89% -13.57% 4.92% 11.56%
WAKEFIELD MUNICIPAL LIGHT DEPT.
TOTAL BILL $115.49 $213.42 $144.38 $1,093.29 $175.48 $5,123.08 $852,765.30
PER KWH CHARGE $0.15398 $0.14228 $0.14438 $0.14977 $0.16249 $0.14637 $0.12396
% DIFFERENCE 6.85% 15.56% 10.10% 11.79% -9.96% 12.86% 17.86%
TOWN OF READING MUNICIPAL LIGHT DEPARTMENT
RATE COMPARISONS READING 8 SURROUNDING TOWNS
June -17
PEABODY MUNICIPAL LIGHT PLANT
TOTAL BILL $88.38 $172.43 $117.07 $952.31 $151.07 $4,709.23 $638,286.46
PER KWH CHARGE $0.11784 $0.11495 $0.11707 $0.13045 $0.13988 $0.13455 $0.09278
%DIFFERENCE -19.80% -8.72% -12.61% -4.01% -23.30% 2.22% -13.35%
MIDDLETON MUNICIPAL LIGHT DEPT.
TOTAL BILL $98.74 $201.66 $132.75 $959.51 $168.44 $4,762.93 $807,171.40
PER KWH CHARGE $0.13165 $0.13444 $0.13275 $0.13144 $0.15596 $0.13608 $0.11733
%DIFFERENCE -10.40% 6.75% -0.91% -3.29% -14.49% 3.38% 9.58%
WAKEFIELD MUNICIPAL LIGHT DEPT.
TOTAL BILL $115.49 $213.42 $144.38 $1,093.29 $175.48 $5,123.08 $852,765.30
PER KWH CHARGE $0.15398 $0.14228 $0.14438 $0.14977 $0.16249 $0.14637 $0.12396
%DIFFERENCE 4.80% 12.98% 7.78% 10.20% -10.91% 11.20% 15.77%
INDUSTRIAL - TOU
RESIDENTIAL
RESIDENTIAL-TOU
RES. HOT WATER
COMMERCIAL
SMALL COMMERCIAL
SCHOOL RATE
109,600 kWh's
760 kWh's
1500 kWh's
1000 kWh's
7,300 kWh's
1,080 kWh's
36000 kWh's
260.000 kW Demand
75126 Split
26.000 kW Demand
10.000 kW Demand
130.6 kW Demand
80120 Split
READING MUNICIPAL LIGHT DEPT.
TOTAL BILL
$110.19
$188.91
$133.96
$992.11
$196.97
$4,607.05
$736,600.61
PER KWH CHARGE
$0.14692
$0.12594
$0.13396
$0.13591
$0.18238
$0.13163
$0.10707
NATIONAL GRID
TOTAL BILL
$151.90
$358.79
$188.23
$1,454.38
$223.69
$5,412.22
$975,136.26
PER KWH CHARGE
$0.20253
$0.23919
$0.18823
$0.19923
$0.20712
$0.15463
$0.14174
%DIFFERENCE
37.85%
89.93%
40.51%
46.59%
13.56%
17.48%
32.38%
EVERSOURCE(NSTAR)
TOTAL BILL
$143.50
$253.51
$189.19
$1,233.41
$203.03
$6,692.17
$1,037,846.34
PER KWH CHARGE
$0.19133
$0.16901
$0.18919
$0.16896
$0.18799
$0.19120
$0.15086
%DIFFERENCE
30.23%
34.20%
41.23%
24.32%
3.08%
45.26%
40.90%
PEABODY MUNICIPAL LIGHT PLANT
TOTAL BILL $88.38 $172.43 $117.07 $952.31 $151.07 $4,709.23 $638,286.46
PER KWH CHARGE $0.11784 $0.11495 $0.11707 $0.13045 $0.13988 $0.13455 $0.09278
%DIFFERENCE -19.80% -8.72% -12.61% -4.01% -23.30% 2.22% -13.35%
MIDDLETON MUNICIPAL LIGHT DEPT.
TOTAL BILL $98.74 $201.66 $132.75 $959.51 $168.44 $4,762.93 $807,171.40
PER KWH CHARGE $0.13165 $0.13444 $0.13275 $0.13144 $0.15596 $0.13608 $0.11733
%DIFFERENCE -10.40% 6.75% -0.91% -3.29% -14.49% 3.38% 9.58%
WAKEFIELD MUNICIPAL LIGHT DEPT.
TOTAL BILL $115.49 $213.42 $144.38 $1,093.29 $175.48 $5,123.08 $852,765.30
PER KWH CHARGE $0.15398 $0.14228 $0.14438 $0.14977 $0.16249 $0.14637 $0.12396
%DIFFERENCE 4.80% 12.98% 7.78% 10.20% -10.91% 11.20% 15.77%
From: Tracy Schultz
To: RMLD Board Members Grouo
Subject: AP Warrants and Payroll
Date: Thursday, June 08, 2017 7:38:00 AM
Good morning,
There were no questions on the May 12, May 26, and June 2, 2017 AP Warrants.
Mr. Hennessy had a question on the May 19 AP -the tree trimming contractor
charges for labor and per span removed.
There were no questions on the May 15 Payroll.
Mr. O'Rourke had an inquiry about the May 29, 2017 Payroll: it was a tuition
reimbursement payment to an employee.
This message will be included in the packet for next Thursday's Board Meeting.
Tracy Schultz
Executive Assistant
Reading Municipal Light Department
230 Ash Street. Reading. MA. 01867
Tel: 781.942.6489